EECA 2024 Compliant AHU Commissioning

EECA 2024 Compliant AHU Commissioning

分类: Testing & Commissioning (T&C) for New AHUs 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Testing & Commissioning (T&C): EECA 2024 Compliant AHU Commissioning

As of May 2026, the Energy Efficiency and Conservation Act (EECA) 2024 is in full enforcement across Malaysia. For building owners and facility managers in Kuala Lumpur and Selangor, AHU commissioning is no longer a standard mechanical handover—it is a statutory verification of your building's Energy Intensity Performance. Under the new Act, office buildings exceeding 8,000 $m^2$ are legally required to maintain a minimum 2-Star BEI Rating, making high-efficiency AHU commissioning the primary tool for compliance.

 

At EKG (Malaysia) SDN BHD, our commissioning protocols are engineered to satisfy the Suruhanjaya Tenaga (ST) audit requirements, ensuring your facility avoids the statutory fines (up to RM100,000) associated with non-compliance.

 


1. The EECA 2024 Statutory Framework

Commissioning under the 2026 mandate requires empirical proof that the AHU contributes to a lower Building Energy Intensity (BEI).


2. Precision Commissioning Modules

Our mechanical specialists perform a multi-layered audit to ensure the unit is "Audit-Proof."

Commissioning Phase 2026 Statutory Requirement EKG Implementation
Volumetric Traverse ±10% Design Airflow AHU Airflow Test to ensure IAQ standards are met without over-ventilation.
Leakage Validation SMACNA Seal Class A Zero-leakage verification at the Zero-Leakage Snap-Lock Duct Collars.
VFD Logic Stress Test Static Pressure Reset Proving the BMS can ramp down the fan during partial loads to save energy.
Hydronic Verification High Delta T ($5.5^\circ\text+$ ) Ensuring the chilled water coil isn't "short-circuiting" energy back to the chiller.

3. Engineering for "Laminar Integrity"

The success of an EECA-compliant commissioning process depends on the quality of the AHU Ducting Service.

  1. ESP Verification: We measure the actual External Static Pressure against design. If the ductwork is too restrictive, the fan must work harder, spiking your BEI.

     

  2. Acoustic Signature: We verify the unit operates within the NC 30-35 target. Under the 2026 Indoor Environmental Quality (IEQ) standards, energy efficiency must not come at the cost of occupant comfort.

  3. Trap Prime Validation: We verify the 1:100 statutory slope and P-trap seal. A dry trap is an energy leak (unconditioned air bypass) and a violation of DOSH 2026 hygiene codes.


4. The "Fire Mode" Statutory Witness Test

Commissioning is the final step in securing your annual Fire Certificate (FC) from BOMBA (JBPM) 2026.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU commissioning documented for the 2026 statutory energy audit?

Contact EKG (Malaysia) SDN BHD today for a professional EECA 2024 Compliant AHU Commissioning & Performance Audit.