AHU Condensate Drainage Solutions | Reliable & Hygienic Water Removal by EKG (Malaysia) Sdn Bhd
Prevent Water Damage, Mold Growth, and System Downtime
Effective condensate drainage is critical for any Air Handling Unit (AHU). A failed or inadequate system can lead to overflow, ceiling damage, microbial growth, and impaired indoor air quality. EKG (Malaysia) Sdn Bhd provides complete engineered drainage solutions—from pump selection and installation to maintenance and emergency service—ensuring your AHU removes moisture safely, reliably, and in compliance with health and building standards.
Insufficient Gravity Drainage: AHU located below or far from the main drain point.
Clogged Drain Lines: Build-up of algae, sludge, or scale blocking flow.
Pump Failure: Failed condensate pump or float switch causing overflow.
Inadequate Capacity: Undersized drainage for high-humidity loads or large AHUs.
Poor Access & Maintenance: Difficult-to-service installations leading to neglect.
Missing Safeguards: Lack of overflow alarms or secondary backup systems.
Condensate Pump Systems:
Sump-Based Pumps: For AHUs with drain pans, featuring reliable float switches and alarm contacts.
In-Line Condensate Pumps: Compact units installed directly in the drain line for confined spaces.
Heavy-Duty Pumps: For large AHUs, hospitals, or data centers with high condensate volumes.
Gravity Drainage Optimization:
Correct drain line sizing and slope calculation.
Installation of clean-out tees, vent lines, and trap primers to maintain proper flow.
Hygienic & Maintenance-Friendly Design:
Use of antimicrobial materials and easy-access installation.
Design of dual-pump systems with alternation for critical applications.
Installation of visual and BMS-integrated overflow alarms.
Preventive Maintenance Services:
Regular cleaning and disinfecting of drain pans and lines.
Testing of pumps, switches, and alarm systems.
Water treatment recommendations to prevent biological growth.
Hospital & Healthcare AHUs (critical for infection control)
Data Center & Telecom Precision Cooling Units
Shopping Mall & High-Rise Building Central AHUs
Hotel & Laboratory Air Filtration Systems
Industrial Make-Up Air & Humidity Control Units
Prevents Structural Damage: Avoids costly repairs to ceilings, walls, and electrical systems.
Maintains IAQ (Indoor Air Quality: Eliminates conditions for mold, bacteria, and allergen growth.
Ensures System Uptime: Prevents AHU shutdowns triggered by safety overflow switches.
Reduces Energy Waste: A clogged drain can increase humidity load and cooling energy use.
Complies with Regulations: Meets health, safety, and green building standards.
Site Survey & Risk Assessment: Evaluating AHU location, condensate volume, and failure consequences.
System Design & Specification: Selecting the correct pump capacity, materials, and control strategy.
Professional Installation: Neat, code-compliant installation with proper sealing and labeling.
Testing & Commissioning: Verifying flow rate, alarm function, and integration with BMS.
Maintenance Planning: Scheduling regular service to ensure long-term reliability.
HVAC-Focused Expertise: We understand air handling systems and condensation dynamics.
Hygiene & Compliance Aware: Solutions designed for sensitive environments like hospitals and labs.
Reliability-First Design: We prioritize fail-safes and redundancy where needed.
Single-Source Responsibility: From design to ongoing maintenance, we provide complete accountability.
Secure Your Building from Water Damage and Air Quality Risks
Don't let condensate drainage be an afterthought. Contact EKG (Malaysia) Sdn Bhd for a professional assessment and a reliable, code-compliant solution.
Contact us for a drainage system audit, emergency response to an overflow, or to design a new installation.