Insulation/Continuity Tester possesses the following features:
1. Measurement of insulation resistance
| Technical parameters |
Technical index |
| display | Large-screen LCD (up to 500 counts). |
| Over limit indication: |
Hi: The mark appears on insulation resistance range. |
| Auto range: | Higher range: 500 counts Lower range: 1 count (only on insulation resistance range) |
| Sampling Rate: |
2 times / second. |
| Allowed altitude: |
≤2000m (for indoor use) |
| Operation environment: |
Temperature: 0℃-40 ℃ / Humidity: ≤85% |
| Operation environment: |
Temperature: -20 ℃ -60 ℃ / Humidity: ≤90% |
| Overload protection: |
Insulation resistance range: AC 1200V / 10 seconds Voltage range: AC 720V / 10 seconds |
| Withstand voltage: |
AC 6000V (50 / 60Hz) / 5 seconds (between circuit and periphery |
| Insulation resistance: |
≥1000MΩ/ DC 1000V (between circuit and periphery) |
| power supply | DC9V (6x1.5V AA batteries) |
| Current consumption: |
Approximately 1.5A (maximum) (normally maintained at approximately 50mA) |
| Battery Life: | About 12 hours |
| Dimension: | 176x110x77mm |
Malaysia