详情
Chamber furnaces LH 15/12 - LF 120/14 are suitable for many different glass applications. They are available with either a robust insulation of light refractory bricks (LH models) or with a combination insulation of refractory bricks in the corners and low heat storage, quickly cooling fiber material (LF models). With a wide variety of optional equipment, these chamber furnaces can be adapted optimally and individually to suit your processes.
- Tmax 1200 °C, 1300 °C, or 1400 °C
- Dual shell housing with rear ventilation, provides for low shell temperatures
- High furnace chamber with five-sided heating for very good temperature uniformity
- Heating elements on support tubes ensure free heat radiation and a long service life
- Controller mounted on furnace door and removable for comfortable operation
- Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor
- LH models: multi-layered insulation of light refractory bricks and special backup insulation
- LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times
- Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
- Motorized exhaust air flap
- Freely adjustable air inlet integrated in furnace floor
- Base included
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
- Controller B500 (5 prgrams with each 4 segments)
Additional Equipment
- Parallel swinging door (user protected from heat radiation)
- Lift door with electro-mechanic linear drive for opening when hot
- Cooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume. Both operating modes can be switched on and off for different segments by means of the extra function of the controller.
- Protective gas connection to purge with non-flammable protective or reaction gases
- Manual or automatic gas supply system
- Stainless steel exhaust hood as interface to customer’s exhaust system
- Process control and documentation via VCD software package for monitoring, documentation and control
- Parallel swinging door (user protected from heat radiation)
- Lift door with electro-mechanic linear drive for opening when hot
- Cooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume. Both operating modes can be switched on and off for different segments by means of the extra function of the controller.
- Protective gas connection to purge with non-flammable protective or reaction gases
- Manual or automatic gas supply system
- Stainless steel exhaust hood as interface to customer’s exhaust system
- Process control and documentation via VCD software package for monitoring, documentation and control
| Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions1 in mm |
Connected |
Electrical |
Weight |
| |
in °C |
w |
d |
h |
in l |
W |
D |
H |
load in kW |
connection |
in kg |
| LH 15/12 |
1200 |
250 |
250 |
250 |
15 |
680 |
860 |
1230 |
5.0 |
3-phase2 |
170 |
| LH 30/12 |
1200 |
320 |
320 |
320 |
30 |
710 |
930 |
1290 |
7.0 |
3-phase2 |
200 |
| LH 60/12 |
1200 |
400 |
400 |
400 |
60 |
790 |
1080 |
1370 |
8.0 |
3-phase |
300 |
| LH 120/12 |
1200 |
500 |
500 |
500 |
120 |
890 |
1180 |
1470 |
12.0 |
3-phase |
410 |
| LH 216/12 |
1200 |
600 |
600 |
600 |
216 |
990 |
1280 |
1590 |
20.0 |
3-phase |
450 |
| |
|
|
|
|
|
|
|
|
|
|
|
| LH 15/13 |
1300 |
250 |
250 |
250 |
15 |
680 |
860 |
1230 |
7.0 |
3-phase2 |
170 |
| LH 30/13 |
1300 |
320 |
320 |
320 |
30 |
710 |
930 |
1290 |
8.0 |
3-phase2 |
200 |
| LH 60/13 |
1300 |
400 |
400 |
400 |
60 |
790 |
1080 |
1370 |
11.0 |
3-phase |
300 |
| LH 120/13 |
1300 |
500 |
500 |
500 |
120 |
890 |
1180 |
1470 |
15.0 |
3-phase |
410 |
| LH 216/13 |
1300 |
600 |
600 |
600 |
216 |
990 |
1280 |
1590 |
22.0 |
3-phase |
460 |
| |
|
|
|
|
|
|
|
|
|
|
|
| LH 15/14 |
1400 |
250 |
250 |
250 |
15 |
680 |
860 |
1230 |
8.0 |
3-phase2 |
170 |
| LH 30/14 |
1400 |
320 |
320 |
320 |
30 |
710 |
930 |
1290 |
10.0 |
3-phase2 |
200 |
| LH 60/14 |
1400 |
400 |
400 |
400 |
60 |
790 |
1080 |
1370 |
12.0 |
3-phase |
300 |
| LH 120/14 |
1400 |
500 |
500 |
500 |
120 |
890 |
1180 |
1470 |
18.0 |
3-phase |
410 |
| LH 216/14 |
1400 |
600 |
600 |
600 |
216 |
990 |
1280 |
1590 |
26.0 |
3-phase |
470 |
| |
|
|
|
|
|
|
|
|
|
|
|
| LF 15/13 |
1300 |
250 |
250 |
250 |
15 |
680 |
860 |
1230 |
7.0 |
3-phase2 |
150 |
| LF 30/13 |
1300 |
320 |
320 |
320 |
30 |
710 |
930 |
1290 |
8.0 |
3-phase2 |
180 |
| LF 60/13 |
1300 |
400 |
400 |
400 |
60 |
790 |
1080 |
1370 |
11.0 |
3-phase |
270 |
| LF 120/13 |
1300 |
500 |
500 |
500 |
120 |
890 |
1180 |
1470 |
15.0 |
3-phase |
370 |
| |
|
|
|
|
|
|
|
|
|
|
|
| LF 15/14 |
1400 |
250 |
250 |
250 |
15 |
680 |
860 |
1230 |
8.0 |
3-phase2 |
150 |
| LF 30/14 |
1400 |
320 |
320 |
320 |
30 |
710 |
930 |
1290 |
10.0 |
3-phase2 |
180 |
| LF 60/14 |
1400 |
400 |
400 |
400 |
60 |
790 |
1080 |
1370 |
12.0 |
3-phase |
270 |
| LF 120/14 |
1400 |
500 |
500 |
500 |
120 |
890 |
1180 |
1470 |
18.0 |
3-phase |
370 |
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
2Heating only between two phases |
更多 Obsnap Instruments Sdn. Bhd. 相关资料