| SPECIFICATIONS | 
		
			| Conductor | 
		
			| AWG | 22 | 
		
			| Stranding | 7x30 | 
		
			| Material | BC - Bare Copper | 
		
			| Nominal Diameter | 0.03 in | 
		
			| No. of Coax | 1 | 
		
			| Insulation | 
		
			| Material | PE - Polyethylene (Foam) | 
		
			| Nominal Diameter | 0.146 in | 
		
			| Outer Shield Material | 
		
			| Type | Braid | 
		
			| Material | Braid Bare Copper (BC) | 
		
			| Coverage (%) | 95% | 
		
			| Outer Jacket Material | 
		
			| Material | PVC - Polyvinyl Chloride | 
		
			| Nominal Diameter | 0.241 in | 
		
			| Conductor DCR | 
		
			| Nominal Conductor DCR | 15 Ohm/1000ft | 
		
			| Nominal Outer Shield DCR | 2.6 Ohm/1000ft | 
		
			| Outer Conductor DCR | 2.6 Ohm/1000ft | 
		
			| Capacitance | 
		
			| Nom. Capacitance Conductor to Shield | 17.3 pF/ft | 
		
			| Inductance | 
		
			| Nominal Inductance | 0.09 µH/ft | 
		
			| Impedance | 
		
			| Nominal Characteristic Impedance | 75 Ohm | 
		
			| Delay | 
		
			| Nominal Delay | 1.3 ns/ft | 
		
			| Nominal Velocity of Propagation (VP) (%) | 78% | 
		
			| Temperature Range | 
		
			| Operating Temp Range | -30°C To +60°C | 
		
			| Mechanical Characteristics | 
		
			| Bulk Cable Weight | 33 lbs/1000ft | 
		
			| Max. Pull Tension | 65 lbs | 
		
			| Min Bend Radius/Minor Axis | 2.5 in | 
		
			| Standards | 
		
			| CPR Euroclass | Fca | 
		
			| RG Type | 59/U Type | 
		
			| Applicable Environmental and Other Programs | 
		
			| Environmental Space | Indoor (Not Riser or Plenum) | 
		
			| EU Directive 2000/53/EC (ELV) | Yes | 
		
			| EU Directive 2003/96/EC (BFR) | Yes | 
		
			| EU Directive 2011/65/EU (ROHS II) | Yes | 
		
			| EU Directive 2012/19/EU (WEEE) | Yes | 
		
			| EU Directive 2015/863/EU | Yes | 
		
			| EU Directive Compliance | EU Directive 2003/11/EC (BFR) | 
		
			| EU CE Mark | No | 
		
			| EU RoHS Compliance Date (yyyy-mm-dd) | 2004-01-01 | 
		
			| MII Order #39 (China RoHS) | Yes | 
		
			| Suitability | 
		
			| Suitability - Burial | Yes | 
		
			| Suitability - Indoor | Yes | 
		
			| Suitability - Outdoor | Yes | 
		
			| Plenum/Non-Plenum | 
		
			| Plenum (Y/N) | No |