CE Marking for DC 3-wire models and AC/DC 2-wire models
Noise-resistant models are also available for environments with strong noise
| 
			 Model  | 
			
			 E2K-C25M[]1  | 
			
			 E2K-C25M[]2  | 
			
			 E2K-C25MY1  | 
			
			 E2K-C25MY2  | 
		|
| 
			 Sensing distance *  | 
			
			 25 mm  | 
		||||
| 
			 Sensing distance adjustable  | 
			
			 3 to 25 mm  | 
		||||
| 
			 Detectable object  | 
			
			 Conductors and dielectrics  | 
		||||
| 
			 Standard sensing object  | 
			
			 Grounded metal plate: 50 × 50 × 1 mm  | 
		||||
| 
			 Differential travel  | 
			
			 15% max. of sensing sensing distance (when adjusted to 25 mm ±10% with standard  | 
		||||
| 
			 Response frequency  | 
			
			 70 Hz  | 
			
			 10 Hz  | 
		|||
| 
			 Power supply voltage  | 
			
			 12 to 24 VDC (10 to 30 VDC), ripple (p-p):  | 
			
			 100 to 220 VAC (90 to 250 VAC), 50/60 Hz  | 
		|||
| 
			 Current consumption  | 
			
			 E and F Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC  | 
		||||
| 
			 Leakage current  | 
			
			 Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200  | 
		||||
| 
			 Control  | 
			
			 Load current  | 
			
			 200 mA max.  | 
			
			 5 to 200 mA (resistive load)  | 
		||
| 
			 Residual voltage  | 
			
			 2 V max. (Load current: 200 mA, Cable  | 
			
			 Refer to Engineering Data on Data Sheet  | 
		|||
| 
			 Indicators  | 
			
			 Detection indicator (red)  | 
			
			 Operation indicator (red)  | 
		|||
| 
			 Operation mode  | 
			
			 E1, F1, and Y1 Models: NO  | 
		||||
| 
			 Protection circuits  | 
			
			 Reverse polarity protection,  | 
			
			 Surge suppressor  | 
		|||
| 
			 Ambient temperature range  | 
			
			 Operating/Storage: -25 to 70°C (with no icing or condensation)  | 
		||||
| 
			 Ambient humidity range  | 
			
			 Operating/Storage: 35% to 95% (with no condensation)  | 
		||||
| 
			 Temperature influence  | 
			
			 ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C  | 
		||||
| 
			 Voltage influence  | 
			
			 ±2% max. of sensing distance at the rated  | 
			
			 ±2% max. of sensing distance at the rated  | 
		|||
| 
			 Insulation  | 
			
			 50 MΩ min. (at 500 VDC) between current-carrying parts and case  | 
		||||
| 
			 Dielectric strength  | 
			
			 1,000 VAC, 50/60 Hz for 1 min between  | 
			
			 1,500 VAC, 50/60 Hz for 1 min between  | 
		|||
| 
			 Vibration  | 
			
			 Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z  | 
		||||
| 
			 Shock resistance  | 
			
			 Destruction: 500 m/s2 10 times each in X, Y, and Z directions  | 
		||||
| 
			 Degree of protection  | 
			
			 IEC 60529 IP66  | 
		||||
| 
			 Connection method  | 
			
			 Pre-wired Models (Standard cable length: 2 m)  | 
		||||
| 
			 Weight (packed state)  | 
			
			 Approx. 200 g  | 
		||||
| 
			 Materials  | 
			
			 Case  | 
			
			 Heat-resistant ABS  | 
		|||
| 
			 Sensing surface  | 
		|||||
| 
			 Accessories  | 
			
			 Mounting Bracket, Sensitivity adjustment driver, M4 screws, Instruction manual  | 
		||||
Malaysia