• Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only 10 mm thick.)
• Direct mounting onto a metallic surface is possible
| 
			 Model  | 
			
			 E2K-F10MC[]-A  | 
			
			 E2K-F10MC[]  | 
		|
| 
			 Sensing distance  | 
			
			 10 mm (Sensing distance adjustable  | 
			
			 10 mm ±10%  | 
		|
| 
			 Set distance  | 
			
			 0 to 7.5 mm *  | 
		||
| 
			 Differential travel  | 
			
			 15% max. of sensing distance  | 
		||
| 
			 Detectable object  | 
			
			 Conductors and dielectrics  | 
		||
| 
			 Standard sensing object  | 
			
			 Grounded metal plate: 50 × 50 × 1 mm  | 
		||
| 
			 Response frequency  | 
			
			 100 Hz  | 
		||
| 
			 Power supply voltage  | 
			
			 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  | 
		||
| 
			 Current consumption  | 
			
			 10 mA max. at 24 VDC  | 
		||
| 
			 Control  | 
			
			 Load current  | 
			
			 NPN open collector, 100 mA max. (at 30 VDC)  | 
		|
| 
			 Residual voltage  | 
			
			 1.5 V max. (Load current: 100 mA, Cable length: 2 m)  | 
		||
| 
			 Indicators  | 
			
			 Detection indicator (red)  | 
		||
| 
			 Number of turns of  | 
			
			 11 turns  | 
			
			 -  | 
		|
| 
			 Operation mode (with  | 
			
			 NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.)  | 
		||
| 
			 Protection circuits  | 
			
			 Reverse polarity protection, Surge suppressor  | 
		||
| 
			 Ambient temperature range  | 
			
			 Operating/Storage: -10 to 55°C (with no icing or condensation)  | 
		||
| 
			 Ambient humidity range  | 
			
			 Operating/Storage: 35% to 95%  | 
			
			 Operating/Storage: 35% to 95%  | 
		|
| 
			 Temperature influence  | 
			
			 ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C  | 
		||
| 
			 Voltage influence  | 
			
			 ±2.5% max. of sensing distance at rated voltage at rated voltage ±10%  | 
		||
| 
			 Insulation resistance  | 
			
			 50 MΩ min. (at 500 VDC) between current-carrying parts and case  | 
		||
| 
			 Dielectric strength  | 
			
			 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case  | 
		||
| 
			 Vibration resistance  | 
			
			 Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z  | 
		||
| 
			 Shock resistance  | 
			
			 Destruction: 500 m/s2 3 times each in X, Y, and Z directions  | 
		||
| 
			 Degree of protection  | 
			
			 IP64 (IEC)  | 
			
			 IP66 (IEC)  | 
		|
| 
			 Connection method  | 
			
			 Pre-wired Models (Standard cable length: 2 m)  | 
		||
| 
			 Weight (packed state)  | 
			
			 Approx. 35 g  | 
		||
| 
			 Materials  | 
			
			 Case  | 
			
			 Heat-resistant ABS  | 
		|
| 
			 Sensing surface  | 
		|||
| 
			 Accessories  | 
			
			 Adjustment screwdriver, Instruction manual  | 
		||
Malaysia