Product lineup with M12, M18, and M30 models
Fixed sensing distance requires no sensitivity adjustment
| 
			 Model  | 
			
			 E2K-X4ME  | 
			
			 E2K-X8ME  | 
			
			 E2K-X15ME  | 
		|
| 
			 Sensing distance  | 
			
			 4mm ±10%  | 
			
			 8 mm ±10%  | 
			
			 15 mm ±10%  | 
		|
| 
			 Set distance *1  | 
			
			 0 to 2.8 mm  | 
			
			 0 to 5.6 mm  | 
			
			 0 to 10 mm  | 
		|
| 
			 Differential travel  | 
			
			 4% to 20% of sensing distance  | 
		|||
| 
			 Detectable object  | 
			
			 Conductors and dielectrics  | 
		|||
| 
			 Standard sensing object  | 
			
			 Grounded metal plate: 50 × 50 × 1 mm  | 
		|||
| 
			 Response frequency  | 
			
			 E and F Models: 100 Hz, Y Models: 10 Hz  | 
		|||
| 
			 Power supply voltage *2  | 
			
			 E and F Models: 12 to 24 VDC (10 to 30 VDC)  | 
		|||
| 
			 Current consumption  | 
			
			 E and F Models: 15 mA max.  | 
		|||
| 
			 Leakage current  | 
			
			 Y Models: 2.2 mA max. (Refer to Datasheet.)  | 
		|||
| 
			 Control  | 
			
			 Load current  | 
			
			 E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA  | 
		||
| 
			 Residual  | 
			
			 E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m),  | 
		|||
| 
			 Indicators  | 
			
			 E and F Models: Detection indicator (red), Y Models: Operation indicator (red)  | 
		|||
| 
			 Operation mode  | 
			
			 E1, F1, and Y1 Models: NO  | 
		|||
| 
			 Protection circuits  | 
			
			 E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit  | 
		|||
| 
			 Ambient temperature  | 
			
			 Operating/Storage: -25 to 70°C  | 
			
			 Operating/Storage: -10 to 55°C  | 
		||
| 
			 Ambient humidity range  | 
			
			 Operating/Storage: 35% to 95% (with no condensation)  | 
		|||
| 
			 Temperature influence  | 
			
			 ±20% max. of sensing distance at 23°C in the operating temperature range  | 
		|||
| 
			 Voltage influence  | 
			
			 E and F Models: ±2% max. of sensing distance at rated voltage at rated voltage ±20%  | 
		|||
| 
			 Insulation resistance  | 
			
			 50 MΩ min. (at 500 VDC) between current-carrying parts and case  | 
		|||
| 
			 Dielectric strength  | 
			
			 E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  | 
		|||
| 
			 Vibration resistance  | 
			
			 Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z  | 
		|||
| 
			 Shock resistance  | 
			
			 Destruction: 500 m/s2 3 times each in X, Y, and Z directions  | 
		|||
| 
			 Degree of protection  | 
			
			 IP66 (IEC), in-house standards: oil-resistant  | 
		|||
| 
			 Connection method  | 
			
			 Pre-wired Models (Standard cable length: 2 m)  | 
		|||
| 
			 Weight (packed state)  | 
			
			 Approx. 65 g  | 
			
			 Approx. 145 g  | 
			
			 Approx. 205 g  | 
		|
| 
			 Materials  | 
			
			 Case  | 
			
			 Heat-resistant ABS  | 
		||
| 
			 Sensing  | 
		||||
| 
			 Clamping nuts  | 
			
			 Polyacetal  | 
		|||
| 
			 Accessories  | 
			
			 Instruction manual  | 
		|||
 
Malaysia