Internal Duct Sealing

Internal Duct Sealing

Danh mục: Aerosol Duct Sealing Services Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại eakon.com.my

Mô tả

In the 2026 Malaysian commercial landscape, Internal Duct Sealing (specifically Aerosolized Sealing) is the definitive engineering solution for meeting the strict mandates of the Energy Efficiency and Conservation Act (EECA) 2024.

Unlike traditional manual sealing, which requires physical access to the exterior of the ductwork, internal sealing addresses leaks from the inside out. This makes it the only viable method for repairing "hidden" leaks in vertical risers or ducts buried behind fixed plaster ceilings in high-rise offices across Kuala Lumpur and Selangor.


1. The Technology: "Inside-Out" Aerosol Sealing

The industry standard for internal sealing is the Aeroseal process. It treats the entire duct network as a single pressure vessel.

The Process Workflow:

 
  1. System Isolation: All terminal diffusers and grilles are blocked with temporary foam plugs. The AHU (Air Handling Unit) and sensitive components like VAV boxes are bypassed to protect internal electronics.

  2. Pressurization & Baseline Test: A computerized diagnostic fan pressurizes the system to identify the current leakage rate (measured in $L/s$ or $CFM$).

  3. Sealant Injection: A non-toxic, water-based polymer mist is injected into the pressurized air stream. The particles remain suspended in the air until they reach a leak site.

  4. Targeted Bridge Building: As air attempts to escape through a gap, the particles collide with the edges of the leak and bond together, "building" a seal across gaps up to 15mm wide.


2. Strategic Benefits for 2026 Compliance

A. EECA 2024 & BEI Optimization

Under the EECA 2024, large commercial buildings must maintain a specific Building Energy Index (BEI).

B. Achieving Airtightness Class 6 (ATC 6)

Following the 2026 update to MS 1525, ATC 6 is now the benchmark for high-performance buildings. Internal aerosol sealing is the only method capable of verifying that a system has reached $<1\%$ leakage, as the software provides a Certificate of Airtightness with real-time digital proof of the reduction.

C. DOSH ICOP IAQ 2026 Hygiene

Internal sealing ensures that return air ducts are hermetic. This prevents "plenum aspiration"—the suction of dusty, humid air from contaminated ceiling voids. This is essential for passing the mandatory 500 cfu/m³ bacterial ceiling required for healthy Malaysian workspaces.


3. Comparison: Internal vs. External Sealing

Feature External Manual Sealing Internal Aerosol Sealing
Accessibility Requires full visual access No access needed (Internal path)
Leak Coverage 40% – 50% (Visible only) 95% – 99% (Comprehensive)
Demolition Required High (Ceiling removal) None (Zero Disruption)
Verification Visual / Smoke test Computerized Pressure Report
Best Used For Exposed Mechanical Rooms Hidden Risers & Inaccessible Ducts
EECA 2024 Status Basic / Maintenance Audit-Grade Compliance

4. Implementation with EKG M&E Sdn Bhd

As your M&E partner, we integrate internal sealing with Total 3D BIM Coordination. We model your duct network in 3D to identify high-resistance "choke points" and optimize the aerosol delivery path.

Is your facility's energy efficiency being sabotaged by inaccessible duct leaks? Contact EKG M&E Sdn Bhd today for a professional internal duct sealing audit and secure the performance of your infrastructure.


Expert Guide: Are you planning to treat an existing building to improve its Energy Star Rating, or are you working on the commissioning of a new Grade-A office tower?

Xem thêm chi tiết về EKG M & E SDN BHD