KEYENCE KV-XL402

KEYENCE KV-XL402

Danh mục: KEYENCE Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại wesotechdigital.com

Mô tả

Model KV-XL402
Type Serial communication unit
Communication standard RS-422A RS-485 (4 wires), RS-422A RS-485 (2 wires)
Connection interface European terminal block with 5 poles (detachable) × 2 ports
Transmission specifications Electrical termination (terminator) ON/OFF set by the switch on the front face
Transmission rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps
Transmission method RS-422A RS-485 (4 wires): Full duplexRS-422A RS-485 (2 wires): Half duplex
Data format Start bit: 1 bitData bit: 7 bits, 8 bitsStop bit: 1 bit, 2 bits
Error detection Parity: Even, odd, none
RS/CS flow control ON or OFF (only in PLC link mode)
Transmission distance Total extension: 1200 m 3937.0′ max. twelfth
Number of transmission units 32 *1
Refresh Automatic refresh, direct refresh, inter-unit synchronization refresh
Serial communication functions Non-procedure, PROTOCOL STUDIO, Modbus slave, etc.
Serial communication function execution methods Ladder program, unit program (flow)
Unit program capacity 3 MB (Max. number of blocks: Approx. 20000)
flow Max. number of flows 256
Number of simultaneous activities Unlimited
Flow Internal data Memory 524288 words
PROTOCOL STUDIO Transmission method Cyclic communication: Tx + Rx, Tx only, Rx onlyEvent communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx, Break Tx
Max. number of connected devices 2
Max. number of communication commands 48/96 *3
Maximum number of total frames Rx: 48/96 *3 × 16;Tx: 48/96 *3 × 1
Max. number of compared received frames 16 per command
Maximum number of block elements 96 per frame
Transmission data length 1 to 2048 bytes per frame
Reception data length
PLC link Communication patterns Write, read, transfer
Number of link settings 512 settings max. *4
Link data size 1440 words max. per setting (bit: 720 words, word: 720 words)737280 words max. (total) (1440 words × 512 settings)
Data unit 1 word
Number of connected models 2 models max. (1 model × 2 ports)
Number of connected units 2 max. (1 unit × 2 ports)
Trigger types Cyclic/event (64 settings max. for event *4 )
Update interval 10 to 65535 ms
Internal current consumption 150 mA or less
Weight Approx. 190 g