The HR11 Series 1:1 Rack Online UPS is the perfect power protection solution for small data centers. This series supports built-in battery options, and the 6kVA and 10kVA models utilize advanced 3-level technology, ensuring compatibility with complex load conditions. Available models include 1kVA, 2kVA, 3kVA, 6kVA, and 10kVA.
Wide input voltage range with input power factor >99%
Compatible with standard 19” racks and matching battery cabinets
Comprehensive protection against overvoltage, short circuits, and overheating
LCD/LED display for real-time system monitoring
Smart fan control with automatic speed adjustment
Versatile communication interfaces: RS232, USB, SNMP, Intelligent Card
High efficiency operation – up to 95%
True power output: kVA = kW, with power factor of 1
Smart charging management to enhance battery lifespan
Advanced 3-level inverter technology for superior load compatibility
| HR1101S | HR1101L | HR1102S | HR1102L | HR1103S | HR1103L | |
| INPUT | ||||||
| Cold Start | YES, default frequency=50Hz or settable | |||||
| Acceptable Input Voltage | 110VAC~288VAC | |||||
| 100% load@>176VAC | ||||||
| 80% load@>154VAC | ||||||
| 70% load@>132VAC | ||||||
| 50% load@>110VAC | ||||||
| Phase | Single phase in,single phase out | |||||
| Transfer Voltage Range | (200VAC/208VAC/220VAC/230VAC/240VAC) | |||||
| -Line low transfer | 110VAC | |||||
| -Line low recovery | 121VAC | |||||
| -Line high transfer | 288VAC | |||||
| -Line high recovery | 281VAC | |||||
| Input Current | ||||||
| -Rating(nominal input voltage) | 4.8A | 9.6A | 14.4A | |||
| Input Power Factor | ≥0.97 | |||||
| Input Connection | IEC C14 | IEC C20 | IEC C20 | |||
| Input Frequency Range | 40~70Hz | |||||
| OUTPUT | ||||||
| Frequency adaptable | Settable | |||||
| Power | ||||||
| -Power(kVA) max | 1 | 2 | 3 | |||
| -Power(kW) max | 0.9(0.8 for 200VAC/208VAC) | 1.8(1.6 for 200VAC/208VAC) | 2.7(2.4 for 200VAC/208VAC) | |||
| Output Voltage | ||||||
| -Waveform(Bat. Mode) | Pure Sine Wave | |||||
| -Nominal voltage | 200/208/220/230/240VAC | |||||
| -Voltage regulation | ± 1 % | |||||
| -Transient response | ≤5% (0% - 100% -0%) | |||||
| -Transient recovery | ≤30ms (0% - 100% -0%) | |||||
| -Voltage distortion | ≤2% THD, linear load | |||||
| ≤ 5.5% THD, non-linear load | ≤ 5% THD, non-linear load | ≤ 5% THD, non-linear load | ||||
| Output Frequency | ||||||
| -Synchronization range | ±5Hz default | |||||
| -Battery mode | (50±0.1) Hz default | |||||
| Transfer Time | ||||||
| -Line mode to battery mode | 0 | |||||
| -Inverter to bypass | 2ms | |||||
| Efficiency | ||||||
| -Line mode with battery full charged | 89%@100% load, 87%@50% load | 91%@100% load, 88%@50% load | 90%@100% load, 90%@50% load | |||
| -ECO mode | 94.0% | 97.0% | 97.0% | |||
| -Battery mode | 83%@100% load, 84%@50% load | 87%@100% load, 88%@50% load | 87%@100% load, 89%@50% load | |||
| Noise(1m away) | <45dB@<60%load,<50dB@>60%load | <50dB@<60%load,<55dB@>60%load | <50dB@<60%load,<55dB@>60%load | |||
| Overload Capability(Inverter) | 105%~130%: Transfer to bypass after 1 mins. | |||||
| 150%: Transfer to bypass after 30s | ||||||
| Overload Capability(Battery Mode) | 105%~130%:shutdown after 10s | |||||
| 150%:shutdown after 5s | ||||||
| Overload Capability (Bypass Mode) | <130%: Long time | |||||
| >130%&<150%:Shutdown after 10min | ||||||
| >150%&<180%:Shutdown after 5 seconds | ||||||
| Output Connection | (6) IEC C13 | (6) IEC C13 | (6)IEC C13+(1)IEC C19 | |||
| Crest Ratio | 3:1 | |||||
| BATTERY | ||||||
| Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries |
| Quantity | 3 | 6 | 8 | |||
| DC Voltage | 36VDC | 72VDC | 96VDC | |||
| Back-up Time | 6mins @80% load | Depend on the capacity of external batteries | 6mins @80% load | Depend on the capacity of external batteries | 5.5mins @80% load | Depend on the capacity of external batteries |
| Battery-Low Voltage | 33VAC~35VDC depending on load | 66VDC~70VDC depending on load | 88VDC~94VDC depending on load | |||
| Backery Maintenance | Front Maintenance Online | |||||
| Charger | ||||||
| -Charging voltage | float:40.5VDC/boost:41.4VDC | float:81VDC/boost:82.8VDC | float:108VDC/boost:110.4VDC | |||
| -Charging current (max) | 1A | 8A or 4A | 1A | 8A or 4A | 1A | 8A or 4A |
| -Charging time | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
| Leakage current | <1mA | <1mA | <1mA | |||
| INDICATOR & ALARM | ||||||
| -Display | LED+LCD | |||||
| -Battery discharge | Sounding every 2 minutes | |||||
| -Low battery | Sounding every 6 seconds | |||||
| -Overload | Continuous beeping | |||||
| -Fault | Continuous beeping | |||||
| -Input voltage abnormal | Sounding every 2 minutes | |||||
| -Warn | Sounding every 6 seconds | |||||
| INTERFACE | ||||||
| -Smart RS232 | Standard Cable support INVT Power Monitor Software | |||||
| -SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||||
| OPTION | ||||||
| -Intelligent Kits | DB9 port, dry contact | |||||
| -USB | B-type USB port | |||||
| -SNMP Kits | pluggable type | |||||
| MECHANICAL | ||||||
| -W%sD%sH (mm) | 438*426*86(2U) | 438*426*86(2U) | 438*476*173(4U) | 440*476*86(2U) | 438*476*173(4U) | 438*476*86(2U) |
| (max) | 438*437*86 | 438*437*86 | 438*488*173 | 440*488*86 | 438*488*173 | 438*488*86 |
| -W%sD%sH (mm)(shipment) | 580*565*250 | 580*565*250 | 580*660*335 | 580*615*250 | 580*660*335 | 580*615*250 |
| -Net Weight (KG) | 13.5 | 8 | 28 | 9.5 | 33 | 10.5 |
| -Package Weight(KG) | 16 | 11 | 31 | 12.5 | 36 | 13.5 |
| -Rack / Tower | Rack and Tower | |||||
| Color | Black default | |||||
| HR1106XS | HR1106XL | HR1110XS | HR1110XL | |
| INPUT | ||||
| Cold Start | YES Default output frequency will be 50Hz or settable |
|||
| Acceptable Input Voltage | 110VAC~288VAC | |||
| 100% load@>176VAC | ||||
| 90% load@>154VAC | ||||
| 75% load@>132VAC | ||||
| 50% load@>110VAC | ||||
| Phase | Single phase in,single phase out | |||
| Transfer Voltage Range | 200VAC/208VAC/220VAC/230VAC/240VAC | |||
| -Line low transfer | 110VAC | |||
| -Line low recovery | 121VAC | |||
| -Line high transfer | 288VAC | |||
| -Line high recovery | 281VAC | |||
| Input Current | ||||
| -Rating(full charging) | 30A/220V | 34A/220V | 49A/220V | 53A/220V |
| Input Power Factor | ≥0.99 | |||
| Input current distortion | <4% | |||
| Input Frequency Range | 40~70Hz | |||
| OUTPUT | ||||
| Frequency adaptable | Settable | |||
| Power | ||||
| -Power | 6KVA | 10KVA | ||
| -Power(kW) | 6KW | 10KW | ||
| Output Voltage | ||||
| -Waveform(Bat. Mode) | Pure Sine Wave | |||
| -Nominal voltage | 220VAC/230VAC/240VAC, 200VAC/208VAC(PF=0.9) | |||
| -Voltage regulation | ± 1 % | |||
| -Voltage distortion | ≤1% THD, linear load | |||
| ≤ 5% THD, non linear load | ||||
| Output Frequency | ||||
| -Synchronization range | ±5Hz default, settable | |||
| -Battery mode | (50±0.1) Hz default | |||
| Transfer Time | ||||
| -Line mode to battery mode | 0ms | |||
| -Inverter to bypass | 0ms | |||
| Efficiency | ||||
| -Line mode with battery full charged | 94.6%@100% load, 95%@60% load | |||
| -ECO mode | 98.0% | |||
| Noise(1m away) | <58dB | |||
| Overload Capability(Inverter) | 105% to 110% : Transfer to bypass after 10 mins. | |||
| 111% to 125% : Transfer to bypass after 1 mins. | ||||
| 126% to 150%: Transfer to bypass after 30s | ||||
| Overload Capability (Bypass Mode) | less than 125%: long time running | |||
| 126% to 130% :Shutdown in 5 mins | ||||
| 131% to 150% :Shutdown in 1 mins | ||||
| > 150% :Shutdown in 200 ms | ||||
| Crest Ratio | 3:1 | |||
| BATTERY | ||||
| Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries |
| Quantity | 16PCS | 16-20PCS settable | 16PCS | 16-20PCS settable |
| DC Voltage | 192VDC default, settable | |||
| Back-up Time | 3mins @5kW | Depend on the capacity of external batteries | 2mins @8kW | Depend on the capacity of external batteries |
| Charger | ||||
| -Charging current (max) | 1A, settable | 5A max,settable | 1A,settable | 5A max,settable |
| -Float Charging Voltage | 2.25V/cell default, setttable via software | |||
| -Boost Charging Voltage | 2.25V/cell default, setttable via software | |||
| -Charging time | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
| Leakage current | <3mA | |||
| Indicator & Alarm | ||||
| -Display | LED+LCD | |||
| Inteface | ||||
| -Smart RS232 | Standard Cable support INVT Power Monitor Software | |||
| -EPO | NC | |||
| -RS485(option) | Installed in the intelligent slot | |||
| -SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||
| Option | ||||
| -Intelligent Kits | DB9 port, dry contact | |||
| -parallel | 4 units paralleled | |||
| -Super charger (12A) | digitally controlled, 4-steps charge, settable, @PF0.9 | |||
| -USB | B-type USB port | |||
| -SNMP Kits | Pluggable type | |||
| Mechanical | ||||
| -W%sD%sH (mm) | 440*660*172 | 440*550*86 | 440*660*172 | 440*550*86 |
| -Net Weight (KG) | 58 | 16 | 62 | 18 |
| -Package Weight (KG) | 63 | 18 | 68 | 21 |
| -Rack / Tower | Rack/Tower | |||
| Color | Black default | |||