Easy to use low profile center hole load cell!
Capacity 1 kN/ 2 kN/ 5 kN/ 10 kN/ 20 kNSuitable for measurement of axial bolt force, press-fitting, and caulking.
| Model | UBFH- 1KN |
UBFH- 2KN |
UBFH- 5KN |
UBFH- 10KN |
UBFH- 20KN |
|---|---|---|---|---|---|
| Rated capacity | 1 kN | 2 kN | 5 kN | 10 kN | 20 kN |
| Rated output | Approx. 1 mV/V | ||||
| Safe overload | 150% R.C. | ||||
| Zero balance | ±10% R.O. | ||||
| Non-linearity | 0.1% or less R.O. | 0.2% or less R.O. | 0.5% or less R.O. | ||
| Hysteresis | 0.2% or less R.O. | 0.5% or less R.O. | |||
| Repeatability | 0.1% or less R.O. | 0.3% or less R.O. | |||
| Compensated temperature range |
-10 to +60℃ | ||||
| Safe temperature range |
-10 to +70℃ | ||||
| Temperature effect on zero |
0.3% R.O./10℃ or below | ||||
| Temperature effect on span |
0.2% R.O./10℃ or below | ||||
| Input resistance | Approx. 1000 Ω | ||||
| Output resistance | Approx. 1000 Ω | ||||
| Recommended excitation voltage |
10 V | ||||
| Maximum excitation voltage |
15 V | ||||
| Insulation resistance | 1000 MΩ or more | ||||
| Cable | φ3.8 4-conductor flexible cable (3 m) Cable end: 5 wires |
||||
| Cable color code | +EXC:Red +SIG:Green -EXC:Black -SIG:White SHIELD:Yellow |
||||
| Deflection at rated | 0.030 mm | 0.035 mm | |||
| Natural frequency | 5.0 kHz | 7.3 kHz | 11 kHz | 9.7 kHz | 13 kHz |
| Load cell material | Stainless steel | ||||
| Weight | 280 g | 470 g | |||
| RoHS directives | 2011/65/EU (EU)2015/863 | ||||