Model: MICT-150Y
Fast Temperature Change Test Chamber Main Parameters:
Temperature range: -40℃~150℃
Rapid-rate temperature range: -40℃~+85℃
Ramp rate:7℃/ min( non-linear type)
| Model | MICT-150Y | |
| Inner chamber size(mm) |
500*600*500 (W*H*D) |
|
| Exterior chamber size (cm) | Depends on chamber design | |
| Testing temperature range |
-40℃~150℃ |
|
| Rapid-rate temperature range |
-40℃~+85℃ |
|
| Temperature gradient |
7℃/ min (linear or non-linear,empty loading),customization is available |
|
| Temp. fluctuation | ±0.3℃ | |
| Temp. uniformity | ±1.5℃(empty loading after stabilizing for 30 mins) | |
| Temp. resolution | 0.01℃ | |
| Exterior chamber material | Cold-rolled plate + Powder coating | |
| Interior chamber material | SUS#304 Stainless steel | |
| Insulation material | PU+ fiberglass wool | |
| Circulation system | Centrifugal fan air circulation system | |
| Heating system | SUS# Stainless steel high-speed heater | |
| Refrigeration system | Compressor + Finned evaporator + Air(Water) cooled condenser | |
| Controlling system | Touch screen controller+SSR+PID | |
| Other components | Vacuum glass observation window | |
| Test hole (50mm) | ||
| Control status indicator | ||
| Interior light | ||
| Compartment shelf (2 freely adjustable) | ||
| Safety protection device | Overheat protection circuit breaker | |
| Compressor overload protection | ||
| Control system overload protection | ||
| Overload indicator | ||
| Phase sequence protection | ||
| High voltage and low voltage protection | ||
| Over-temperature protection | ||
| Fan overcurrent protection | ||
| Power supply | AC 3Ψ380V 60/50Hz | |
| Customization service | Non-standard or special requirements are all welcome | |