| SPECIFICATIONS |
| Conductor |
| AWG |
22 |
| Stranding |
7x30 |
| Material |
BC - Bare Copper |
| Nominal Diameter |
0.03 in |
| No. of Coax |
1 |
| Insulation |
| Material |
PE - Polyethylene (Foam) |
| Nominal Diameter |
0.146 in |
| Outer Shield Material |
| Type |
Braid |
| Material |
Braid Bare Copper (BC) |
| Coverage (%) |
95% |
| Outer Jacket Material |
| Material |
PVC - Polyvinyl Chloride |
| Nominal Diameter |
0.241 in |
| Conductor DCR |
| Nominal Conductor DCR |
15 Ohm/1000ft |
| Nominal Outer Shield DCR |
2.6 Ohm/1000ft |
| Outer Conductor DCR |
2.6 Ohm/1000ft |
| Capacitance |
| Nom. Capacitance Conductor to Shield |
17.3 pF/ft |
| Inductance |
| Nominal Inductance |
0.09 µH/ft |
| Impedance |
| Nominal Characteristic Impedance |
75 Ohm |
| Delay |
| Nominal Delay |
1.3 ns/ft |
| Nominal Velocity of Propagation (VP) (%) |
78% |
| Temperature Range |
| Operating Temp Range |
-30°C To +60°C |
| Mechanical Characteristics |
| Bulk Cable Weight |
33 lbs/1000ft |
| Max. Pull Tension |
65 lbs |
| Min Bend Radius/Minor Axis |
2.5 in |
| Standards |
| CPR Euroclass |
Fca |
| RG Type |
59/U Type |
| Applicable Environmental and Other Programs |
| Environmental Space |
Indoor (Not Riser or Plenum) |
| EU Directive 2000/53/EC (ELV) |
Yes |
| EU Directive 2003/96/EC (BFR) |
Yes |
| EU Directive 2011/65/EU (ROHS II) |
Yes |
| EU Directive 2012/19/EU (WEEE) |
Yes |
| EU Directive 2015/863/EU |
Yes |
| EU Directive Compliance |
EU Directive 2003/11/EC (BFR) |
| EU CE Mark |
No |
| EU RoHS Compliance Date (yyyy-mm-dd) |
2004-01-01 |
| MII Order #39 (China RoHS) |
Yes |
| Suitability |
| Suitability - Burial |
Yes |
| Suitability - Indoor |
Yes |
| Suitability - Outdoor |
Yes |
| Plenum/Non-Plenum |
| Plenum (Y/N) |
No |