Mô tả
QEED Universal Signal Converter
QA-OMNI Advanced Universal Signal Converter
The QEED QA-OMNI is an advanced universal signal converter for current, voltage, frequency, potentiometer and temperature inputs. It supports RTD and thermocouple measurement, programmable analogue retransmission, relay alarm output, RS485 Modbus RTU communication and USB datalogging.
It is designed for industrial automation, process monitoring, BMS, EMS, SCADA, PLC, machine panels and IoT applications where different field signals must be converted, isolated, logged and transmitted to a supervisory system.
Universal Input
Current, voltage, frequency, RTD, TC and potentiometer
Outputs
0 20mA, 0 10V, relay and RS485
Isolation
4-way galvanic isolation
Datalogging
USB pen drive logging with RTC
Overview
QA-OMNI is suitable when a project has multiple possible signal types and a flexible universal converter is required. One module can be configured for voltage, current, temperature, potentiometer, resistance or frequency signals, reducing the need to keep different converter models for different applications.
The device provides analogue retransmission, digital Modbus RTU data and a programmable alarm contact. It can also perform USB datalogging with timestamped data, making it useful for commissioning, troubleshooting, temporary measurement and permanent monitoring.
Positioning: Universal signal converter with 4-way isolation, analogue output, relay alarm, RS485 Modbus and USB datalogging for industrial monitoring and automation.
Key Features
Universal Signal Input
Supports current, voltage, frequency, potentiometer, RTD and thermocouple input types.
Programmable Analogue Output
Provides configurable 0 20mA or 0 10V output for retransmission to PLC, BMS or EMS.
Relay Alarm Output
5A SPDT relay contact can be configured for alarm or threshold output.
RS485 Modbus RTU
Communicates as a Modbus RTU slave through terminals or optional base module connection.
USB Datalogging
Logs data through USB On-The-Go with a pen drive, with RTC timestamping.
DIN Rail Mounting
Compact 17.5mm module for control panels, automation panels and monitoring enclosures.
Supported Inputs
| Input Type |
Supported Signal |
Notes |
| Voltage |
Programmable up to 10Vdc |
100kΩ input impedance, 1mV resolution |
| Current |
Programmable up to 20mA |
20Ω input impedance, max resolution 2 礎 |
| RTD |
Pt100, Pt500, Pt1000, Ni100 |
2, 3 or 4 wire measurement with automatic cable interruption detection |
| Thermocouple |
Types J, K, R, S, T, B, E, N |
Automatic cable interruption detection, -10mV to 70mV range |
| Potentiometer |
1000Ω to 10kΩ |
Suitable for position and resistance-based measurement |
| Frequency |
0.001Hz to 9.99kHz |
Mechanical contact, NPN, PNP, NAMUR, photoelectric, Hall sensor, variable reluctance, 24V pulse and TTL |
Output Functions
| Output |
Specification |
Typical Use |
| Current Output |
0 20mA programmable, maximum load resistance 600Ω |
Retransmission to PLC, controller, BMS, EMS or recorder |
| Voltage Output |
0 10V programmable, minimum load resistance 2kΩ |
Retransmission to analogue input systems |
| Contact Alarm |
5A / 230Vac SPDT relay, fully programmable by FACILE QA-OMNI |
Alarm, threshold output or control interlock |
| RS485 Modbus |
RS485 Modbus RTU slave on terminals or optional base adapter |
SCADA, PLC, EMS, BMS, IoT gateway and IoTWatt 4.0 integration |
4-Way Isolation
QA-OMNI provides 4-way galvanic isolation between the input, analogue / digital output, RS485 / USB communication and power supply. This helps reduce signal noise, ground loop problems and reference potential issues in industrial panels.
Isolation paths: Input, analogue and digital output, RS485 / USB communication and power supply are galvanically isolated at 1.5kV.
Datalogging Function
QA-OMNI includes USB On-The-Go datalogging using a USB pen drive. The integrated RTC real-time clock allows timestamped storage, and recorded files can be downloaded in Excel-importable format for analysis and reporting.
- USB thumb drive / pen drive datalogging
- Integrated RTC real-time clock
- Excel-importable stored data files
- Useful for commissioning, troubleshooting and trend capture
- Suitable for temporary monitoring and permanent measurement support
Technical Specifications
| Parameter |
Specification |
| Power Supply |
10 to 40Vdc or 20 to 28Vac, 50/60Hz |
| Retransmission Output |
Isolated analogue output, programmable voltage or impressed current; active or passive output supply |
| Sensor Power Supply |
13Vdc, 30mA max |
| Absorption |
Maximum 2.5VA |
| Protection Index |
IP20 |
| Accuracy |
0.1% F.S. |
| Resolution |
16-bit, 15 + sign for thermocouple input |
| Rejection |
50 60Hz |
| Thermal Stability at 25°C |
<100ppm / °C |
| Working Temperature |
-15°C to +65°C |
| Storage Temperature |
-40°C to +85°C |
| Isolation |
Input, analogue / digital output, RS485 / USB and power supply isolated at 1.5kV |
| Humidity |
10% to 90%, non-condensing |
| Altitude |
Up to 2000m a.s.l. |
| Mounting |
DIN rail mounting with removable terminals; optional base connection for RS485 bus and supply |
| Connections |
Removable 5.08mm terminals |
| CE Standards |
EN61000-6-4:2006 + A1:2011; EN61000-6-2:2005; EN61010-1:2010 |
| Dimensions |
17.5 x 100 x 112mm, terminals excluded |
| Datalogger |
Non-volatile memory, USB On-The-Go logging with pen drive, Excel-importable file output, integrated RTC |
| Configuration |
FACILE QA-OMNI software via USB or RS485; DIP switch for Modbus address and baud rate |
Correction note: The old page referenced FACILE QA-VI in the configuration row. This updated page uses FACILE QA-OMNI because the product is QA-OMNI.
Typical Applications
Universal Signal Conversion
Use one converter for voltage, current, frequency, temperature and potentiometer signals.
PLC / SCADA Integration
Convert and isolate field signals before sending them to PLC or SCADA systems.
BMS and EMS Panels
Use in building and energy management systems for mixed sensor signal integration.
Process Monitoring
Convert temperature, frequency, potentiometer and analogue process signals into standard outputs.
Temporary Logging
Use USB datalogging for commissioning, site investigation and trend capture.
IoTWatt 4.0
Can be integrated via RS485 Modbus or compatible input modules into IoTWatt 4.0 systems.
Configuration
QA-OMNI can be configured using the free FACILE QA-OMNI software through USB or RS485. The software allows configuration of input type, conversion range, span, zero, analogue output, relay alarm, logging and Modbus communication settings.
- Select voltage, current, RTD, thermocouple, potentiometer or frequency input
- Configure analogue output type and scaling
- Set span and zero
- Set relay alarm threshold and alarm behaviour
- Configure Modbus address and baud rate
- Configure USB datalogging interval and data storage
- Use DIP switches for basic Modbus address and baud rate settings
Commissioning note: Confirm sensor type, wiring method, input range, output scaling, relay alarm logic and Modbus settings before connecting the converter to a live monitoring or control system.
System Integration
QA-OMNI is suitable for integrating mixed field signals into PLC, SCADA, BMS, EMS, data logger, Modbus gateway and IoTWatt 4.0 systems. Its universal input support reduces the number of separate converter models required in a project.
- Use analogue output for direct PLC or controller input
- Use relay output for alarm or threshold indication
- Use RS485 Modbus RTU for digital monitoring
- Use USB datalogging for site trend capture and troubleshooting