CIRCUTOR Portable Power Quality Analyzer

AR6 Portable Network Analyzer

The CIRCUTOR AR6 is a portable three-phase network and power quality analyzer designed for detailed electrical installation studies, energy audits, load profile analysis, harmonics investigation, transient recording and power quality troubleshooting.

It provides simultaneous measurement of voltage, current and leakage current, with a high-resolution 5.7" colour graphic screen for viewing waveforms, harmonics, phasors and disturbance events directly from the instrument.

CIRCUTOR AR6 Portable Network Analyzer
Measurement Channels 5 voltage inputs and 5 current inputs
Display 5.7" high-resolution colour VGA screen
Power Quality Class B according to IEC / UNE-EN 61000-4-30
Software PowerVision PLUS analysis software

Product Overview

The AR6 is one of CIRCUTOR’s complete portable analyzers for power quality and energy studies. It is designed for engineers who need to record network parameters, identify disturbances, verify installation behaviour and produce evidence-based reports.

The analyzer includes 5 voltage measurement inputs and 5 current channels, allowing measurement of three phases, neutral and leakage current. It can record electrical parameters, power quality events, overvoltage, sags, swells, interruptions, transients, flicker, harmonics, waveforms and energy values.

With its graphical display of phasors, harmonics and wave shapes, the AR6 helps the user quickly detect wiring issues, imbalance, phase displacement, harmonics and supply quality problems.

Positioning: Portable network and power quality analyzer for electrical troubleshooting, energy audits, EN 50160 studies, harmonics analysis, transient recording and installation optimisation.

Typical Power Quality Investigation Workflow

The AR6 is connected to the installation, records all selected parameters and events, and the data can then be analysed using PowerVision PLUS for reporting and diagnosis.

1 Connect Voltage & Current
2 Configure Triggers
3 Record Events
4 Download via USB
5 Analyse in PowerVision

Key Features

Three-Phase and Single-Phase Analysis

Suitable for both single-phase and three-phase electrical networks.

Leakage Current Measurement

Includes simultaneous leakage current measurement together with voltage and current channels.

Power Quality Recording

Records voltage quality events including sags, swells, interruptions, overvoltage and transients.

Graphical Diagnostics

Displays phasors, harmonics and waveforms to help identify installation anomalies quickly.

TRMS Measurement

True RMS measurement of main electrical parameters for accurate field analysis.

Energy Import and Export

Includes measurement of consumed and generated energy for load and generation studies.

Configurable Event Trigger

Trigger menu can be configured by level and time for disturbance recording.

PHOTO Capture

Manual or programmed PHOTO captures of 9-channel waveforms and instantaneous values.

USB Data Download

Recorded data can be downloaded through USB for further analysis and reporting.

Applications

The AR6 can be used to perform a complete electrical installation study, including consumption analysis, load curve review, voltage disturbance investigation, waveform inspection, harmonic study, flicker measurement and transient capture.

Energy Audits

Record load profiles, consumption patterns, demand behaviour and power factor for energy audit studies.

Power Quality Troubleshooting

Investigate voltage sags, swells, interruptions, overvoltage, transients, flicker and waveform distortion.

Harmonics and Imbalance

Analyse voltage / current harmonics, phase imbalance and phase displacement using graphical tools.

Electrical Commissioning

Verify phase sequence, current direction, loading and basic network behaviour during commissioning.

Industrial Fault Investigation

Identify power disturbances affecting drives, PLCs, production machines and sensitive equipment.

EN 50160 Studies

Measure and record network quality parameters for supply quality review and reporting.

Portable Network and Quality Supply Analyzer

CIRCUTOR AR6 portable network and quality supply analyzer
  • 10 measurement inputs: 5 voltage inputs and 5 current inputs.
  • 128 samples per cycle per channel in Class 0.5.
  • 5.7" high-resolution colour screen for waveforms, phasor diagrams and harmonic decomposition.
  • Transient and power quality network recording according to EN 50160 and Class B according to IEC 61000-4-30.
  • Configurable internal and external features, including phase colour identification according to project or regulation requirements.
  • Memory optimisation by programming recording periods and special recording conditions.
  • Compatible with flexible clamps with built-in amplifier, including AM54-FLEX and AMS14-FLEX.

Main Technical Specifications

Category AR6 Specification
Analyzer Type Portable network and power quality analyzer for three-phase and single-phase electrical networks
Measurement Class Class 0.5 in measurement
Power Quality Standard Class B according to UNE-EN / IEC 61000-4-30
Network Quality Recording Measurement and recording according to EN 50160
Voltage Inputs U1, U2, U3, UN and earthing
Current Inputs I1, I2, I3, IN and leakage current
Voltage Measurement Range 10 to 800V phase-neutral
Current Measurement Range 0.01 to 1000A, depending on selected clamp
Voltage Input Bandwidth 3.2kHz
Internal Memory 1GB, FAT32
Display 5.7" colour VGA graphic screen
Communications USB
Operating Temperature 0°C to 50°C
Humidity 5% to 95%, without condensation
Altitude Up to 2000m
Dimensions 283 × 168 × 80mm
Weight 1.640kg

Power Supply and Measurement Inputs

Item Specification
External Power Supply Voltage 100 to 240Vac
External Power Supply Current 3.33A
Frequency 50 to 60Hz
External Supply Maximum Power 40W
AR6 Nominal Voltage 12Vdc
AR6 Current 2A
AR6 Maximum Power 24W
Consumption 30VA
Current Input Voltage 0 to 2V
Current Input Impedance 10kΩ
Current Measurement Margin 1% to 120% of In
Maximum Current 3In
Maximum Admissible Voltage 2,500V
Transformation Ratios Programmable

Accuracy and Safety

Parameter Accuracy / Rating
Voltage 0.5% ± 2 digits
Current 0.5% ± 2 digits
Active Power 1% ± 2 digits
Reactive Power 1% ± 2 digits
Enclosure Double insulation
Keyboard Movement and function keys
Safety Category Category III - 600V according to IEC / EN 61010
Safety Rating Below 2000m 1000V CAT III / 600V CAT IV
Safety Rating Above 2000m 1000V CAT III / 600V CAT III / 300V CAT IV
Compliance CE marking
Accuracy note: Accuracy depends on measurement conditions and excludes errors introduced by external clamps and voltage transformers. Correct clamp selection and installation are important for reliable results.

Recorded and Displayed Parameters

Electrical Parameters

Voltage, current, power, energy, power factor, phase values and network behaviour.

Power Quality Events

Sags, swells, interruptions, overvoltage, transients and voltage quality events.

Waveform Capture

Displays and records wave shapes and transient waveforms for detailed investigation.

Harmonics

Graphical harmonic display helps identify distortion and harmonic-related problems.

Phasor Diagram

Phasor display helps identify imbalance, phase shifts, wiring errors and load behaviour.

Flicker

Flicker measurement supports supply quality and disturbance investigation.

Analysis with PowerVision PLUS

Recorded data from the AR6 can be analysed using CIRCUTOR PowerVision PLUS software. This allows engineers to review recorded values, analyse disturbance tables, inspect waveforms, prepare reports and identify optimisation opportunities in electrical installations.

  • Review recorded power quality events and disturbance lists.
  • Analyse load curves and consumption profiles.
  • Study harmonics, flicker, waveform behaviour and transients.
  • Prepare energy audit and power quality investigation reports.
  • Support troubleshooting of machines, panels, feeders and utility supply problems.

Recommended Use in Energy Audit and Power Quality Work

  • Use for temporary logging at incomers, feeders, MCC panels, transformer secondary panels and major equipment panels.
  • Record load curve, kW, kVA, kvar, power factor and energy behaviour before recommending corrective actions.
  • Check voltage sags, swells, harmonics, imbalance and transients affecting sensitive equipment.
  • Use waveform, phasor and harmonic screens for quick on-site diagnostics.
  • Use recorded data as supporting evidence for power quality reports and energy audit findings.
  • Pair AR6 field measurements with IoTWatt 4.0 for longer-term monitoring and digital energy audit workflows.

AR6 Supply, Power Quality Study and Energy Audit Support

Saturn Pyro supports CIRCUTOR AR6 portable network analyzers for power quality studies, energy audits, harmonic analysis, transient investigation, load profiling, EN 50160 reporting and IoTWatt 4.0 digital energy audit projects in Malaysia.

Enquire Now

More detail about Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd Energy Meters Supplier Johor Bahru (JB), Energy Management Malaysia, Selangor, Power Quality Analyzers Supply Kuala Lumpur (KL), Penang ~ Saturn Pyro Sdn Bhd
Contact Us flagMalaysia