Description
CIRCUTOR Portable Power Quality Analyzer
AR6 Portable Network Analyzer
The CIRCUTOR AR6 is a portable three-phase network and power quality analyzer designed for detailed electrical installation studies, energy audits, load profile analysis, harmonics investigation, transient recording and power quality troubleshooting.
It provides simultaneous measurement of voltage, current and leakage current, with a high-resolution 5.7" colour graphic screen for viewing waveforms, harmonics, phasors and disturbance events directly from the instrument.
Measurement Channels 5 voltage inputs and 5 current inputs
Display 5.7" high-resolution colour VGA screen
Power Quality Class B according to IEC / UNE-EN 61000-4-30
Software PowerVision PLUS analysis software
Product Overview
The AR6 is one of CIRCUTOR’s complete portable analyzers for power quality and energy studies. It is designed for engineers who need to record network parameters, identify disturbances, verify installation behaviour and produce evidence-based reports.
The analyzer includes 5 voltage measurement inputs and 5 current channels, allowing measurement of three phases, neutral and leakage current. It can record electrical parameters, power quality events, overvoltage, sags, swells, interruptions, transients, flicker, harmonics, waveforms and energy values.
With its graphical display of phasors, harmonics and wave shapes, the AR6 helps the user quickly detect wiring issues, imbalance, phase displacement, harmonics and supply quality problems.
Positioning: Portable network and power quality analyzer for electrical troubleshooting, energy audits, EN 50160 studies, harmonics analysis, transient recording and installation optimisation.
Typical Power Quality Investigation Workflow
The AR6 is connected to the installation, records all selected parameters and events, and the data can then be analysed using PowerVision PLUS for reporting and diagnosis.
1 Connect Voltage & Current
2 Configure Triggers
3 Record Events
4 Download via USB
5 Analyse in PowerVision
Key Features
Three-Phase and Single-Phase Analysis
Suitable for both single-phase and three-phase electrical networks.
Leakage Current Measurement
Includes simultaneous leakage current measurement together with voltage and current channels.
Power Quality Recording
Records voltage quality events including sags, swells, interruptions, overvoltage and transients.
Graphical Diagnostics
Displays phasors, harmonics and waveforms to help identify installation anomalies quickly.
TRMS Measurement
True RMS measurement of main electrical parameters for accurate field analysis.
Energy Import and Export
Includes measurement of consumed and generated energy for load and generation studies.
Configurable Event Trigger
Trigger menu can be configured by level and time for disturbance recording.
PHOTO Capture
Manual or programmed PHOTO captures of 9-channel waveforms and instantaneous values.
USB Data Download
Recorded data can be downloaded through USB for further analysis and reporting.
Applications
The AR6 can be used to perform a complete electrical installation study, including consumption analysis, load curve review, voltage disturbance investigation, waveform inspection, harmonic study, flicker measurement and transient capture.
Energy Audits
Record load profiles, consumption patterns, demand behaviour and power factor for energy audit studies.
Power Quality Troubleshooting
Investigate voltage sags, swells, interruptions, overvoltage, transients, flicker and waveform distortion.
Harmonics and Imbalance
Analyse voltage / current harmonics, phase imbalance and phase displacement using graphical tools.
Electrical Commissioning
Verify phase sequence, current direction, loading and basic network behaviour during commissioning.
Industrial Fault Investigation
Identify power disturbances affecting drives, PLCs, production machines and sensitive equipment.
EN 50160 Studies
Measure and record network quality parameters for supply quality review and reporting.
Portable Network and Quality Supply Analyzer
- 10 measurement inputs: 5 voltage inputs and 5 current inputs.
- 128 samples per cycle per channel in Class 0.5.
- 5.7" high-resolution colour screen for waveforms, phasor diagrams and harmonic decomposition.
- Transient and power quality network recording according to EN 50160 and Class B according to IEC 61000-4-30.
- Configurable internal and external features, including phase colour identification according to project or regulation requirements.
- Memory optimisation by programming recording periods and special recording conditions.
- Compatible with flexible clamps with built-in amplifier, including AM54-FLEX and AMS14-FLEX.
Main Technical Specifications
| Category |
AR6 Specification |
| Analyzer Type |
Portable network and power quality analyzer for three-phase and single-phase electrical networks |
| Measurement Class |
Class 0.5 in measurement |
| Power Quality Standard |
Class B according to UNE-EN / IEC 61000-4-30 |
| Network Quality Recording |
Measurement and recording according to EN 50160 |
| Voltage Inputs |
U1, U2, U3, UN and earthing |
| Current Inputs |
I1, I2, I3, IN and leakage current |
| Voltage Measurement Range |
10 to 800V phase-neutral |
| Current Measurement Range |
0.01 to 1000A, depending on selected clamp |
| Voltage Input Bandwidth |
3.2kHz |
| Internal Memory |
1GB, FAT32 |
| Display |
5.7" colour VGA graphic screen |
| Communications |
USB |
| Operating Temperature |
0°C to 50°C |
| Humidity |
5% to 95%, without condensation |
| Altitude |
Up to 2000m |
| Dimensions |
283 × 168 × 80mm |
| Weight |
1.640kg |
Power Supply and Measurement Inputs
| Item |
Specification |
| External Power Supply Voltage |
100 to 240Vac |
| External Power Supply Current |
3.33A |
| Frequency |
50 to 60Hz |
| External Supply Maximum Power |
40W |
| AR6 Nominal Voltage |
12Vdc |
| AR6 Current |
2A |
| AR6 Maximum Power |
24W |
| Consumption |
30VA |
| Current Input Voltage |
0 to 2V |
| Current Input Impedance |
10kΩ |
| Current Measurement Margin |
1% to 120% of In |
| Maximum Current |
3In |
| Maximum Admissible Voltage |
2,500V |
| Transformation Ratios |
Programmable |
Accuracy and Safety
| Parameter |
Accuracy / Rating |
| Voltage |
0.5% ± 2 digits |
| Current |
0.5% ± 2 digits |
| Active Power |
1% ± 2 digits |
| Reactive Power |
1% ± 2 digits |
| Enclosure |
Double insulation |
| Keyboard |
Movement and function keys |
| Safety Category |
Category III - 600V according to IEC / EN 61010 |
| Safety Rating Below 2000m |
1000V CAT III / 600V CAT IV |
| Safety Rating Above 2000m |
1000V CAT III / 600V CAT III / 300V CAT IV |
| Compliance |
CE marking |
Accuracy note: Accuracy depends on measurement conditions and excludes errors introduced by external clamps and voltage transformers. Correct clamp selection and installation are important for reliable results.
Recorded and Displayed Parameters
Electrical Parameters
Voltage, current, power, energy, power factor, phase values and network behaviour.
Power Quality Events
Sags, swells, interruptions, overvoltage, transients and voltage quality events.
Waveform Capture
Displays and records wave shapes and transient waveforms for detailed investigation.
Harmonics
Graphical harmonic display helps identify distortion and harmonic-related problems.
Phasor Diagram
Phasor display helps identify imbalance, phase shifts, wiring errors and load behaviour.
Flicker
Flicker measurement supports supply quality and disturbance investigation.
Analysis with PowerVision PLUS
Recorded data from the AR6 can be analysed using CIRCUTOR PowerVision PLUS software. This allows engineers to review recorded values, analyse disturbance tables, inspect waveforms, prepare reports and identify optimisation opportunities in electrical installations.
- Review recorded power quality events and disturbance lists.
- Analyse load curves and consumption profiles.
- Study harmonics, flicker, waveform behaviour and transients.
- Prepare energy audit and power quality investigation reports.
- Support troubleshooting of machines, panels, feeders and utility supply problems.
Recommended Use in Energy Audit and Power Quality Work
- Use for temporary logging at incomers, feeders, MCC panels, transformer secondary panels and major equipment panels.
- Record load curve, kW, kVA, kvar, power factor and energy behaviour before recommending corrective actions.
- Check voltage sags, swells, harmonics, imbalance and transients affecting sensitive equipment.
- Use waveform, phasor and harmonic screens for quick on-site diagnostics.
- Use recorded data as supporting evidence for power quality reports and energy audit findings.
- Pair AR6 field measurements with IoTWatt 4.0 for longer-term monitoring and digital energy audit workflows.
AR6 Supply, Power Quality Study and Energy Audit Support
Saturn Pyro supports CIRCUTOR AR6 portable network analyzers for power quality studies, energy audits, harmonic analysis, transient investigation, load profiling, EN 50160 reporting and IoTWatt 4.0 digital energy audit projects in Malaysia.
Enquire Now