PM3000 Power Master Web-Based Mini-SCADA

PM3000 Power Master Web-Based Mini-SCADA

Category: Archmeter Available
For more information, visit our official website at saturnpyro.com

Description

PM3000 Power Master

PM3000 Power Master Web-Based Mini-SCADA

PM3000 Power Master is a web-based Mini-SCADA system for power monitoring, demand control, scheduling control, set-point control and report generation. It is designed for factories, buildings, campuses and facilities that require centralised visibility of electrical consumption, demand, alarms, power quality and reports.

The PM3000 connects to power meters through Ethernet and RS485 communication, provides real-time and historical monitoring, supports remote operation through intranet or internet, and includes automatic report and alarm notification by email.

System Type Web-based Mini-SCADA
Core Functions Monitoring, demand control, scheduling, set-point control and reports
Meter Capacity 1, 16 or 64 power meters depending on ordering code
Communication RS485, Ethernet, Modbus RTU, Modbus TCP/IP, HTTP, SMTP

Product Description

PM3000 Power Master is a compact power monitoring and control platform built for small to medium electrical monitoring projects. It combines power meter data collection, supervisory display, alarm and event recording, historical trend, power quality monitoring, demand control and automatic reporting in one system.

It is suitable where a full SCADA system is too complex, but the site still needs power monitoring, electricity reports, demand control, e-mail alerts, remote web access and integration with third-party supervisory systems.

Corrected model name: Based on the datasheet, the product is PM3000 Power Master, not PA3000.

Ordering Codes and Meter Capacity

Ordering Code Meter Capacity Demand Forecast / Demand Control Positioning Recommended Use
PM3000-0 Manages 1 power meter Supports 1 power meter demand forecast. Single incomer or single main meter application where demand control and monitoring are required for one metering point.
PM3000-1 Manages up to 16 power meters Suitable for normal multi-meter power monitoring and demand control projects. Factory, building or campus electrical monitoring with up to 16 meters.
PM3000-2 Manages up to 64 power meters For power monitoring only, without demand forecast function. Larger monitoring projects where more meters are required and demand forecast is not required.
Selection note: Select PM3000-1 when the site needs normal Mini-SCADA monitoring with up to 16 meters. Select PM3000-2 only when the project needs up to 64 meter monitoring and does not require demand forecast.

Key Features

Power Monitoring

Displays real-time electrical values from connected meters, including voltage, current, power and other electrical parameters.

Power Quality Monitoring

Monitors harmonic distribution, THD, power factor and voltage variation for each channel or meter.

Demand Control

Provides rolling and blocking demand calculation modes with load shedding by sequence or priority.

16 Load Shedding Outputs

Supports electricity demand control with up to 16 channels of load shedding outputs.

TOU Tariff Management

Supports multi-tariff Time-of-Use management, including seasons, date type, recurring holidays and peak / non-peak rate setup.

Automatic Reports

Generates daily and monthly reports, with automatic e-mail export in Excel format to designated addresses.

Alarm and Event Records

Supports up to 30 alarm types and stores up to 6,553 alarm and event records.

Web-Based Remote Access

Built-in web server allows real-time monitoring, setup, historical data download and remote operation through web browser.

USB Backup

Front USB host port allows backup of historic data, reports, alarm records and event records through USB flash drive.

Typical PM3000 System Architecture

PM3000 collects data from power meters through RS485 or Ethernet. It displays live measurements, records trend and alarm data, generates electricity reports, sends e-mail notifications and controls selected loads through digital outputs for demand control.

1 Power Meters
2 RS485 / Ethernet
3 PM3000 Power Master
4 Web / Reports / Alarms
5 Demand Control Outputs

Application Architecture

PM3000 supports web-based supervisory control, e-mail reports and alarms, third-party control system integration, direct digital output control and power meter networking through Ethernet or RS485.

PM3000 Power Master Application Architecture

Application Architecture

Hardware Specification

Hardware Item Specification / Function
Power Supply 85–240 VAC, 47–63 Hz, 60 VA, maximum 23 W.
Display 6.4 inch TFT LCD, 640 × 480 pixel resolution, 24-bit colour.
Memory 64 MB RAM, 32 MB Flash, 32 MB DOC and RTC battery backup.
USB Interface 1 × USB host port for data backup and program download.
Keypad and Indicators 7 function keys, 4 arrow keys and 2 LED indicators.
Digital Outputs 16 digital outputs for demand control and load shedding.
RS485 Communication 1 × RS485 interface, Modbus serial communication.
Ethernet Communication 2 × 10/100 Mbps Base-T Ethernet ports.
Ethernet Protocols Modbus TCP/IP, HTTP and SMTP.
Operating Temperature 5°C to 50°C.
Storage Temperature -25°C to 60°C.
Humidity 20% to 80% RH, non-condensing.
Dimensions 196 mm (W) × 196 mm (H) × 135 mm (D) for panel mounting.

Software Functions

Software Function Description
Power Demand Control Provides blocking and rolling demand calculation, sequence or priority load shedding, contracted capacity display, selected control mode, current demand, average demand, demand control parameters, control status and manual load shedding.
Power Measurement Monitoring Displays real-time values from each meter including voltage, current and power values. Supports up to 54 real-time values and digital or bar-chart display for each measurement channel.
Power Quality Monitoring Provides instant monitoring of harmonic distribution, THD, power factor and voltage variation for each channel.
Extended I/O Monitoring Displays remote I/O values and trends and allows PM3000 / PC control through connected meter I/O ports.
Real-Time and Historical Trend Displays real-time power information trends and historical trends. Storage can range from 270 days to 5.6 years depending on recording interval and storage configuration.
Report Inquiry Provides daily and monthly report storage for main meters and sub-meters, including tariff-based energy, demand, power factor and load ratio information.
Alarm and Event Record Supports up to 30 alarm types, records system ON/OFF duration, stores up to 6,553 alarm and event records and can send automatic e-mail alarms.
Controller Function Built-in 4 set-point controller for control and alarm logic.
Schedule Control Controls devices according to preset season, date and hour schedules.
System Setup Supports communication setup, network setup, e-mail setup, system time and screen protection time setup.
Meter Setup Supports meter address and tag name setup, CT/PT ratio setup, wiring setup, table setup for recording information, alarm setup and output setup.
Information Backup Historic data, reports, alarms and event records can be backed up through USB flash drive.
Remote Monitoring and Setup Through web browser, real-time values can be monitored and modified remotely, historical data and reports can be downloaded, and system parameters can be configured.

Software Screens and Monitoring Functions

PM3000 Electricity Measurement Monitoring

Electricity Measurement Monitoring

Displays real-time measurements for each transducer with digital and bar display.

PM3000 Power Measure Display

Power Measure Display

Displays voltage, current, power and other live electrical values from connected meters.

PM3000 Power Quality Display

Power Quality Monitoring

Displays voltage THD and current THD in digits and bar charts, with harmonic level display depending on the connected power meter.

PM3000 Alarm and Event Record

Alarm & Event Record

Displays alarms and events in different colours and supports automatic e-mail alarm notification.

PM3000 Real-Time and Historical Trend

Real-Time & Historical Trend

Displays voltage, current and load trends, with user-selectable historical time period.

PM3000 Web-Based Remote Monitoring

Remote Monitoring

Web browser access allows users to view real-time data and receive daily or monthly reports by e-mail.

PM3000 Report Generation

Report Generation

Generates daily and monthly aggregate and detailed reports for main loops and sub-loops.

PM3000 Demand Control

Demand Control

Displays demand control parameters, measures, demand trend and control information in different colours.

Typical Applications

Factories and Industrial Sites

Monitor main incomers, feeders, major equipment, production areas and electrical demand.

Commercial Buildings

Monitor tenant panels, common services, chillers, AHUs, pumps and electrical distribution points.

University Campuses

Monitor multiple buildings, hostels, laboratories, teaching blocks and facility loads.

Demand Management

Use load shedding outputs to reduce maximum demand and manage contracted capacity.

Power Quality Visibility

Use THD, harmonic distribution, power factor and voltage variation information from connected meters.

Automatic Reporting

Generate daily and monthly electricity usage reports and send reports automatically by e-mail.

Integration with IoTWatt 4.0

PM3000 Power Master can be used as a local Mini-SCADA for power monitoring, reports and demand control. IoTWatt 4.0 can further extend the system into cloud-based energy dashboards, digital energy audit, EECA reporting, baseline tracking and advanced analytics.

  • Use PM3000 for local meter monitoring, alarms, trend viewing and demand control.
  • Use IoTWatt 4.0 for advanced dashboards, analytics, digital energy audit and EECA reporting.
  • Integrate meter data through Modbus RTU, Modbus TCP/IP or gateway architecture.
  • Use demand, energy, power quality and report data for energy performance governance.
  • Support factory, building and campus energy management with both local and cloud visibility.
Integration note: PM3000 can be connected with third-party supervisory systems through Modbus TCP/IP, and meter data can be further integrated into IoTWatt 4.0 depending on the project architecture and available communication access.

Recommended Deployment Checklist

  • Confirm ordering code: PM3000-0, PM3000-1 or PM3000-2.
  • Confirm number of power meters to be monitored.
  • Confirm whether demand forecast and demand control are required.
  • Confirm RS485 or Ethernet communication wiring to connected power meters.
  • Confirm Modbus RTU / Modbus TCP/IP addressing and register mapping.
  • Confirm load shedding output requirement and load priority sequence.
  • Confirm contracted demand, target demand and alarm set-points.
  • Confirm TOU tariff structure, seasons, holidays and date type setup.
  • Confirm e-mail server settings for automatic reports and alarm messages.
  • Confirm web access, network access and remote monitoring requirement.
  • Confirm backup process using USB flash drive.
  • Test meter data, trends, reports, alarms, schedule control and demand control during commissioning.

PM3000 Power Master Supply, Commissioning and IoTWatt 4.0 Integration

Saturn Pyro supports PM3000 Power Master systems for power monitoring, demand control, scheduling control, set-point control, report generation, Modbus meter integration, Mini-SCADA deployment, EMS / BMS / SCADA connectivity and IoTWatt 4.0 digital energy audit projects in Malaysia.

Enquire Now

More detail about Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd Energy Meters Supplier Johor Bahru (JB), Energy Management Malaysia, Selangor, Power Quality Analyzers Supply Kuala Lumpur (KL), Penang ~ Saturn Pyro Sdn Bhd
Contact Us flagMalaysia