Archmeter PA330 Multi-Function Power Meter
PA330 Multi-Function Power Meter
The Archmeter PA330 is a compact 96 mm × 96 mm multi-function power meter designed for single-phase and three-phase electrical monitoring. It provides wide measurement coverage for voltage, current, active power, reactive power, apparent power, energy, power factor, frequency, demand, power quality and operating time.
With Class 0.5 active energy accuracy, built-in RS485 communication, large backlit LCD display, alarm output and pulse / alarm output functions, the PA330 is suitable for panel metering, feeder monitoring, energy management, basic power quality visibility and integration with SCADA, BMS, EMS or IoTWatt 4.0.
Meter Type Single-phase and three-phase multi-function power meter
Accuracy V / I < 0.2%, W 0.5%, Wh < 0.5%
Communication Built-in RS485, optional LonTalk
Display Large mono LCD with adjustable backlight
Product Description
PA330 is designed for modern power monitoring applications where one compact meter must provide electrical measurement, energy monitoring, power quality indication and communication. It measures more than 90 electrical parameters, including voltage, current, power, energy, power factor, frequency, demand, THD, unbalance, voltage eligibility and min / max values.
The meter is housed in a standard DIN 96 mm × 96 mm panel format, making it easy to install in switchboards, distribution boards, MCC panels, control panels and equipment panels. The integrated RS485 port allows the PA330 to be connected to third-party SCADA, BMS, EMS or energy monitoring platforms.
Best use case: PA330 is suitable for cost-effective feeder-level metering where electrical parameters, energy, THD, unbalance, demand, min / max values and RS485 communication are required.
Key Features
IEC 62053-22 Class 0.5
Supports Class 0.5 active energy measurement for reliable energy monitoring and cost allocation applications.
High Measurement Accuracy
Voltage and current accuracy better than 0.2%, active power accuracy 0.5% at PF 1.0 and Wh accuracy better than 0.5%.
Bi-Directional Energy
Supports total, import, export and net energy indication for applications with delivered and received energy flow.
More Than 90 Parameters
Measures voltage, current, power, energy, demand, frequency, power factor, unbalance, THD and min / max values.
Current Direction Setting
Allows correction of display value when CT direction or polarity requires adjustment during commissioning.
Large Backlit LCD
Large 68 mm × 59 mm mono LCD with 4-stage backlight adjustment for easy local operation.
Power Quality Indication
Displays voltage / current THD, voltage / current unbalance, voltage eligibility and min / max values.
RS485 Communication
Built-in RS485 communication makes the meter suitable for integration with SCADA, EMS, BMS and IoTWatt 4.0.
Digital Outputs
Includes two digital outputs: DO1 for alarm output and DO2 for pulse or alarm output.
Measured Parameters
The PA330 front display provides multiple display pages for electrical monitoring. The display includes values for voltage, current, active power, reactive power, apparent power, power factor, frequency, demand, eligibility rate, unbalance rate, energy and time.
| Parameter Group |
Available Measurements / Display Values |
| Voltage |
Line-to-line voltage, line-to-neutral voltage, average voltage and max / min voltage values. |
| Current |
Phase current, average current and max / min current values. |
| Active Power |
Phase and total kW, including max / min active power. |
| Reactive Power |
Phase and total kvar, including max / min reactive power. |
| Apparent Power |
Phase and total kVA, including max / min apparent power. |
| Power Factor |
Total power factor, load characteristic indication and max / min power factor. |
| Frequency |
System frequency, maximum frequency and minimum frequency. |
| Demand |
Previous power demand, current power demand, maximum power demand, minimum power demand and demand subinterval remaining time. |
| Energy |
Total active energy, total reactive energy and total apparent energy. |
| Power Quality |
Voltage THD, current THD, voltage / current unbalance rate and voltage eligibility. |
| Time and Status |
Year / month / day, hour / minute / second, alarm buzzer status, pulse output / communication indicator and DO status. |
Display Functions
| Display Area / Indicator |
Function |
| Main measurement area |
Displays V, I, kW, kvar, kVA, PF, frequency, demand, eligibility rate and unbalance rate. |
| Energy and time area |
Displays energy values and time information. |
| Load percentage indicator |
Provides quick visual loading indication. |
| Unbalance / THD indicators |
Indicates voltage / current unbalance and THD display pages. |
| Measurement type indicator |
Shows the current measurement group such as current, voltage, energy or power. |
| Alarm buzzer icon |
Shows alarm buzzer ON / OFF status. |
| Pulse and communication indicator |
Indicates pulse output and communication activity. |
| Power factor and load characteristic area |
Displays PF and load characteristic indication. |
| Units area |
Displays units such as V, kV, kW, MW, A, kVA, MVA, kvar, Mvar, Hz, %, kWh, kVAh and kvarh. |
| Function buttons |
Front buttons include M, P, E/T and V/A functions. |
| Digital output status |
Shows DO1 and DO2 output status. |
Technical Specification
| Item |
Specification |
| Auxiliary Power |
AC 80–264 V / DC 100–300 V, maximum 2.3 W. |
| Input Voltage |
CAT II, 10 V–600 V line-to-line. |
| Input Current |
2 mA–5 A. |
| Accuracy |
Voltage / current 0.2%, active power 0.5% at PF = 1.0, Wh < 0.5%. |
| Frequency |
45–65 Hz. |
| Measurements |
V, I, kW, kvar, kVA, kWh, kvarh, kVAh, PF, frequency, demand and running hour. |
| Alarms |
None, over voltage / current, over frequency, under voltage / current, under frequency, over demand and general alarm conditions. |
| Power Quality |
Voltage / current THD, voltage / current unbalance, voltage eligibility and min / max parameters. |
| Display |
Mono 68 mm × 59 mm LCD with adjustable backlight. |
| Communication |
1 × RS485, optional LonTalk. |
| Timer |
RTC. |
| Wiring Ports |
Auxiliary power, voltage, current, DO1, DO2, RS485 and optional LON. |
| I/O |
2 digital outputs: DO1 alarm output, DO2 pulse / alarm output. |
| Operating Temperature |
-20°C to 70°C. |
| Storage Temperature |
-25°C to 80°C. |
| Humidity |
20–90% RH. |
| Protection Rating |
Panel: IP52; case: IP20. |
| Dimensions |
96 mm (W) × 96 mm (H) × 97 mm (D). |
| Power Consumption |
0.45–0.7 W with backlight off, 1.3–1.7 W with maximum backlight, maximum 2.3 W with backlight and Lon module. |
Typical Applications
Panel Metering
Use as a compact digital meter for main panels, sub-distribution panels and control panels.
Feeder Monitoring
Monitor incoming or outgoing feeders for voltage, current, power, energy, demand and power factor.
Energy Monitoring
Track kWh, kvarh and kVAh values for cost allocation, usage review and energy performance visibility.
Power Quality Review
Use THD, unbalance and voltage eligibility values for basic power quality awareness.
Alarm Output Applications
Use digital outputs for alarm signalling, pulse output or integration with external systems.
SCADA / BMS / EMS Integration
Use RS485 communication for integration with monitoring systems, gateways or IoTWatt 4.0.
Typical System Integration
PA330 can be installed on a switchboard or equipment panel and connected through RS485 to a gateway, BMS, EMS, SCADA or IoTWatt 4.0. The meter provides live values, energy readings, demand, THD, unbalance and alarm information for remote monitoring.
Integration with IoTWatt 4.0
When connected to IoTWatt 4.0, PA330 meter data can be used for energy dashboards, feeder comparison, load profiling, abnormal consumption detection, power factor review, basic power quality visibility and digital energy audit workflows.
- Monitor kWh, kW, kvar, kVA, voltage, current, frequency and power factor.
- Use demand values to understand feeder loading and peak demand behaviour.
- Use voltage / current THD and unbalance values for basic power quality visibility.
- Use min / max values to identify abnormal operating conditions.
- Use energy data for baseline creation, cost allocation and energy audit evidence.
- Connect through RS485 using a suitable gateway such as RS2LAN, RS2MQTT or RS2WLAN.
Integration note: PA330 is suitable for IoTWatt 4.0 projects where cost-effective RS485 metering is required for distribution boards, feeders, MCC panels and equipment-level monitoring.
Recommended Deployment Checklist
- Confirm the electrical system: single-phase or three-phase.
- Confirm direct voltage input requirement and voltage level.
- Confirm CT ratio, CT secondary, CT class, burden and CT polarity.
- Confirm auxiliary power availability: AC 80–264 V or DC 100–300 V.
- Confirm RS485 communication parameters: address, baud rate, parity and wiring.
- Confirm if optional LonTalk communication is required.
- Confirm alarm output and pulse output requirements for DO1 and DO2.
- Confirm panel cut-out and 96 mm × 96 mm installation clearance.
- Confirm integration with SCADA, BMS, EMS, gateway or IoTWatt 4.0.
- Test voltage phase sequence, CT direction, display values, communication and alarm / pulse outputs during commissioning.
PA330 Meter Supply, Commissioning and IoTWatt 4.0 Integration