Fire-Rated Class 0 AHU Internal Lining

Fire-Rated Class 0 AHU Internal Lining

分类: AHU Internal Lining & Insulation Replacement 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

Industrial AHU Casing & Panel Restoration: Fire-Rated Class 0 Internal Lining

In the 2026 Malaysian industrial sector, a Class 0 Fire Rating for AHU internal linings is a non-negotiable statutory requirement. Under BOMBA (JBPM) 2026 life-safety codes and the Uniform Building By-Laws (UBBL), the air distribution system is classified as a "Fire Highway." If the internal lining of an AHU is combustible, it can act as a fuel source, spreading flames and lethal toxic smoke throughout a building within minutes.

At EKG (Malaysia) SDN BHD, we ensure your units are equipped with Class 0 Certified linings that satisfy both fire safety and the thermal requirements of the Energy Efficiency and Conservation Act (EECA) 2024.


1. The Statutory Mandate: BOMBA (JBPM) 2026

A Class 0 rating is the highest safety standard for surface spread of flame and fire propagation.


2. Engineering the "Fire-Safe" Internal Envelope

We utilize advanced materials that balance life safety with thermodynamic performance.

Material Component Technical Specification Engineering Purpose
Class 0 Elastomeric Foam Nitrile Rubber (NBR) with alumina trihydrate. Provides high $R$-value and acoustic damping while remaining self-extinguishing.
Glass-Cloth Facing Inorganic, non-combustible textile weave. Acts as a "Fire Shield" over the insulation, preventing ignition from spark or heat.
Intumescent Sealants Fire-rated MS Polymers that expand when heated. Seals panel joints to prevent smoke from "leaking" out of the AHU Box.
Mechanical Fasteners Stainless steel pins with fire-rated washers. Ensures the lining does not "slump" or fall during high-temperature events.

3. The "Fire Mode" Pressure Resilience

A fire-rated lining must survive the mechanical stresses of a life-safety event.

  1. Automatic Fire Signal AHU Shut-off: When the fire alarm triggers, the VFD-driven AHU undergoes a sudden, high-torque deceleration or shut-off. The Class 0 lining must be bonded with industrial-grade, heat-resistant adhesives to ensure it does not delaminate under the resulting pressure surge.

  2. Smoke-Tight Integrity: By achieving SMACNA Seal Class A through specialized fire-rated gaskets, we ensure that if smoke enters the unit, it is contained within the casing and not "leaked" into the plant room or ceiling voids.

  3. Low Smoke Toxicity (LST): Beyond just resisting flames, our 2026-spec linings are engineered to produce ultra-low levels of smoke. This ensures that the building's "Respiratory System" does not become a delivery mechanism for toxic fumes.


4. Integration with Energy & Hygiene Standards

At EKG (Malaysia) SDN BHD, we ensure fire safety does not compromise energy health.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU lining combustible, shedding, or failing its annual BOMBA audit?

Contact EKG (Malaysia) SDN BHD today for a professional Fire-Rated Class 0 AHU Internal Lining Audit.