The Super Blower filter is an under- and over-pressure filter designed to run in constant operation.
Constructed as a self-supporting sheet metal construction in high tensile steel modules. Process air is passed into a filter chamber, where the larger particles settle to the bottom of the filter, from where the air is passed through filter bags which retain the residual particles.
The modular SuperBlower filter is a flexible design which can be adapted to any given task in terms of capacity by dimensioning the filter height and the number of filterbags.
Surface: Powder coated to corrosion class C3 cf. ISO 12944.
ATEX SuperBlower filter with PowerPulse® cleaning and external compressed air is ATEX approved and fitted with JKF’s specially developed VFV® explosion relief venting (vertical explosion relief venting through the filter top).
Application
Surface
Powder coated to corrosion class C3 cf. ISO 12944.
Inlet
The SuperBlower filter is available with 180° tangential inlet, standard 706 x 1806 mm or large 1006 x 2106 mm. Inlets can be fitted at both ends of the filter.
Cleaning system
The filter is delivered with PowerPulse®.
Discharge system
Scraper bottom with outlet for rotary valve, screw, bucket or container.
ATEX
SuperBlower filter with PowerPulse® cleaning and external compressed air is ATEX approved and fitted with JKF’s specially developed VFV® explosion relief venting (vertical explosion relief venting through the filter top).
Operating range
Pressure: +/- 5000 Pa
Filter area: 221-1295 m²
Max. operating temperature: 40°C
Min. operating temperature: -10°C
Connection
Gear motor cleaning carriage: 0.18 kW, 20.0 min {¹, 3 x 230 V, 50 Hz, .9 A
Gear motor scraper bottom
2 x 0.75 kW, 17.5 min {¹, 3 x 400 V, 50 Hz, 2 x 2.2 A