HI520 Dual-Channel Universal Process Controller /w Digital Probe Inputs,3 Relays,2 Analog Outputs

HI520 Dual-Channel Universal Process Controller /w Digital Probe Inputs,3 Relays,2 Analog Outputs

分类: Controllers & Transmitters
Option
已售罄
可在官方网站购买
欲了解更多详情,请游览我们的官方网站 hannamalaysia.com

详情

HI520
Dual-Channel Universal Process Controller

Our advanced process controller, the HI520, is designed for applications requiring precise monitoring and control of four key water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen

 

HI520_angleright_720x720
 

Control Modes

Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.

Hold Function

Hold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.

Configurable Alarm System

Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.

Auto-cleaning cycle

The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.


 

520_open_Fuse-Panel_720x720

Relays

Available with up to five electromechanical control relays and one alarm relay.

Analog Outputs

Up to four galvanically isolated analog outputs for control of pumps and valves.

Digital RS485 Output

Can daisy-chain up to 32 devices to a remote monitoring system.

Digital Inputs

Two digital inputs available for modes including disabling, cleaning and placing the controller into hold status.
 



HI510_controller_hold

Large LCD

The LCD displays measurement information along with indicators of potential problems. The DIAG key then provides details of the issue.

HI510_controller_logging

Data-logging

Store info at selectable intervals along with relay control settings and calibrations data. Up to 100 lots, each holding 8600 records. Transfer to a flash drive as a .csv file using the USB Type-C port.

HI510_controller_diagnostic

Help Button

Using the help and diagnostic button (? DIAG) will provide information related to errors or in setup mode, information about settings.
 


SPECIFICATION

Specification Detail
sku HI520
On state 5 to 24 Vdc,
low or high level active
Analog Outputs: 2 or 4 independent,
galvanically isolated outputs 0 22 mA con¯¬gurable as
0 20 mA
Fuse protected 5A,
250V slow blow fuse
Alarm Relay for All Measurement Alarms: Electromechanical relay SPDT contact output 5A 250 VAC,
5A 30 Vdc (resistive load) Fuse protected
5A,
250V slow blow fuse
Dimensions: Width 144.0 mm (5.7in.)
Height 144.0 mm (5.7in.)
Depth 151.3 mm (6.0in.)

 

 


更多 Hanna Instruments (M) Sdn Bhd 相关资料
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd