Position control for doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management with an AWAX controller High temperature : -40 °C à +125 °C Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller
	
		 
	
		- 
			Time before dangerous failure: MTTFd = 100 years
- 
			Max. activation distance: 10 mm, 2 mm hysteresis
- 
			Safety contacts/diagnostics: 2 x NO 1A/24V redundant and
- 
			1 x 250mA PNP contact
- 
			Detection encoding: mono-code inviolable
- 
			Reset: automatic
- 
			Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
- 
			Mounting position: 2 (double wall brackets)
- 
			Material: INOX 316L mirror polished
- 
			Electrical connection: 220cm Ultra-soft silicone cord with M12 connector.
- 
			Water resistance: IP69K (Switch) / IP67 (Connector)
- 
			Extreme temperature: -40°C to +125°C
- 
			Protective cover 316L stainless steel mirror polished ''ref. + C'' option
- 
			Marking: laser engraving with mechanical punching of the serial number for permanent traceability