Model No. |
PTH-80A |
PTH-150A |
PTH-225A |
PTH-416A |
PTH-800A |
PTH-1000A |
PTH-80A |
PTH-150B |
PTH-225B |
PTH-416B |
PTH-800B |
PTH-1000B |
|||
|
Internal Dimensions |
W |
400 |
500 |
500 |
700 |
1000 |
1000 |
400 |
500 |
500 |
700 |
1000 |
1000 |
||
|
|
H |
500 |
600 |
750 |
850 |
1000 |
1000 |
500 |
600 |
750 |
850 |
1000 |
1000 |
||
|
|
D |
400 |
500 |
600 |
700 |
800 |
1000 |
400 |
500 |
600 |
700 |
800 |
1000 |
||
|
External Dimensions (mm) |
W |
930 |
1030 |
1080 |
1230 |
1530 |
1530 |
930 |
1030 |
1080 |
1230 |
1530 |
1530 |
||
|
|
H |
1310 |
1410 |
1620 |
1660 |
1810 |
1810 |
1310 |
1410 |
1620 |
1660 |
1810 |
1810 |
||
|
|
D |
810 |
910 |
1120 |
1210 |
1310 |
1510 |
810 |
910 |
1120 |
1210 |
1310 |
1510 |
||
|
Volume (L) |
80 |
150 |
225 |
416 |
800 |
1000 |
80 |
150 |
225 |
416 |
800 |
1000 |
|||
|
Temperature Range |
0℃~100℃(150℃) |
-20℃~100℃(150℃) |
|||||||||||||
|
The Evenness Of Humiture Distribu tion |
±0.5℃ ±3%RH |
± 1 ℃ ± 5 %R H |
±0.5℃ ±3%RH |
± 1 ℃ ± 5 %R H |
|||||||||||
|
Temperature Rising Speed |
0℃~100℃ about 20min |
-20℃~100℃ about 35min |
|||||||||||||
|
Temperature Falling Speed |
20℃~0℃ about 20min |
20℃~20℃ about 45min |
|||||||||||||
|
Freezing System |
1PC of fully sealed air cooling system |
||||||||||||||
|
Humidity Range |
20%~98%RH |
||||||||||||||
|
Humiture Stability |
±0.2℃ ±2%RH |
||||||||||||||
|
Humiture Adjustment |
Auto balancing temperature and humidity adjustment |
||||||||||||||
|
Outside Materials |
Stainless steel sus # 304 |
||||||||||||||
|
Inside Materials |
Stainless steel sus # 304 |
||||||||||||||
|
Humidifying System |
Surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device. |
||||||||||||||
|
Thermal Material |
Heat preserved by rock wool and hardened pu foaming |
||||||||||||||
|
Heating System |
Heater with stainless steel dissipation |
||||||||||||||
|
Circulatory Syste m |
Convection by fan forced circulatory system |
||||||||||||||
|
Dehumidifying System |
Freezing dehumidifying system |
||||||||||||||
|
Water Supplying System |
The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water. |
||||||||||||||
|
Safety Devices |
Leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, overtemperatureprotection device for humidifier and the protection device for limit of temperature. |
||||||||||||||
|
Standard Delivery |
Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator. |
||||||||||||||
|
Optional Accessories |
Recorder |
||||||||||||||
|
Power |
AC220V/50, AC110V/60HZ |
||||||||||||||
更多 LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 相关资料