Application
Storm water drain
Power duct
Replacement of RCC hume pile at road crossing
Design Consideration
The structure design of Precast RC Box Culvert is in accordance with the requirement of:
BS 5400 : Part 4 : 1990
BD 31/01 The Design of Buried Concrete Box and Portal Frame Structures
MS 1293 : Part 1 : 1992
Box culverts are able to withstand a standard 2m (Max.) of superimposed backfill depth and 45 units of HB vehicle live load.
Standard size box culverts also comply with proof load test of 112.5 kN over an area of 320mm x 320mm placed at any position on the box culvert's lid.
Minimum backfill depth of 600mm over box culverts are recommended to avoid undesirable direct impact load.
Hydrostatic pressure is eliminated by provision of weepholes placed along the centerline of the invert wall.
Types
Standard Size Box Culvert (width from 300mm to 1800mm)
Supersize Box Culvert (width from 2135mm to 3660mm)
* Box culverts are available with / without dry weather flow (DWF) channels. Kindly specify your requirement.
*As sizes can differ between brands, if the size you need isn't available in the variants, please WhatsApp us with your specific size request.*