48KC WeatherMaker® rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.
Gas Heating/Electric Cooling Units
3 to 5 Nominal Tons

| Factory-Installed | Field-Installed | |
| Cabinet | ||
| Thru the base electrical or gas line connections | X | X |
| Hinged access panels | X | |
| Coil Options | ||
|
Cu/Cu indoor and/or outdoor coils |
X | |
| Pre-coated outdoor coils | X | |
| Premium, e-coated outdoor coils | X | |
| Humidity Control | ||
| Humidi-MiZer adaptive dehumidification system (3-phase models only) | X | |
| Condenser Protection | ||
| Condenser coil hail guard (louvered design) | X | X |
| Controls | ||
| Thermostats, temperature sensors and subbases | X | |
| PremierLink DDC communicating controller | X | X |
| RTU Open multi-protocol controller | X | X |
| Smoke detector (supply and/or return air) | X | |
| Time Guard II compressor delay control circuit | X | |
| Filter status switch | X | |
| Fan status switch | X | |
| Economizers & Outdoor Air Dampers | ||
|
EconoMi$er IV (for electro-mechanical controlled RTUs) |
X | X |
|
EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD) |
X | X |
| EconoMi$er 2 (for DDC controlled RTUs) | X | X |
| Ultra-low leak economizer dampers | X | X |
| Motorized 2-position outdoor air damper | X | X |
| Manual outdoor dir damper | X | |
| Barometric relief | X | X |
| Power exhaust | X | |
| Economizer Sensors & IAQ Devices | ||
| Single dry bulb temperature sensors | X | X |
| Differential dry bulb temperature sensors | X | |
| Single enthalpy sensors | X | X |
| Differential enthalpy sensors | X | |
| CO2 sensor (wall, duct, or unit mounted) | X | X |
| Gas Heat | ||
| Liquid propane (LP) conversion kit | X | |
| High altitude conversion kit | X | |
| Indoor Motor & Drive | ||
| Multiple motor and drive packages | X | |
| Low Ambient Control | ||
| Winter start kit | X | |
| Motormaster head pressure controller | X | |
| Power Options | ||
| Convenience outlet (powered) | X | |
| Convenience outlet (unpowered) | X | |
| Non-fused disconnect | X | |
| Roof Curbs | ||
| Roof curb 14'' (356mm) | X | |
| Roof curb 24'' (610mm) | X | |
| Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) EER | Dimensions (in) LxWxH | Low Gas Heating Input (MBtuh) | Medium Gas Heating Input (MBtuh) | High Gas Heating Input (MBtuh) | Approx. Unit Weight (lbs) |
|---|---|---|---|---|---|---|---|
| 3 | 1 | (14.0) | 74x47x33 | 72 | 115 | - | 490 |
| 4 | 1 | (14.0) | 74x47x33 | 72 | 115 | 150 | 544 |
| 5 | 1 | (14.1) | 74x47x41 | 72 | 115 | 150 | 597 |