Acoustic Sound-Attenuated Ducting Setup

Acoustic Sound-Attenuated Ducting Setup

Category: AHU Ducting & Terminal Connection Setup Available
For more information, visit our official website at eakon.com.my

Description

AHU Ducting & Terminal Connection Setup: Acoustic Sound-Attenuated Ducting

In the 2026 Malaysian engineering landscape, Acoustic Sound-Attenuated Ducting is a technical necessity for Grade-A offices, healthcare facilities, and recording studios. As AHUs become more powerful to meet EECA 2024 airflow requirements, managing the "Regenerated Noise" from high-velocity air and the "Break-out Noise" from the fan motor is critical for achieving NC 30-35 acoustic ratings.

At EKG (Malaysia) SDN BHD, we engineer sound-attenuated setups to be Sterile, Silent, and Statutory-Compliant, ensuring your facility meets the comfort standards of MS 1525:2024.


1. The Engineering Components of Acoustic Ducting

A silent ducting setup utilizes a multi-layered approach to absorb sound energy before it reaches the terminal outlet.


2. Statutory Acoustic Standards: MS 1525:2024

The updated Malaysian standards provide strict Noise Criteria (NC) levels for different indoor environments. Failure to meet these can lead to occupant dissatisfaction and building audit failures.

Environment 2026 NC Target Engineering Requirement
Executive Boardrooms NC 25 - 30 Requires 2-stage attenuation (Main duct + Terminal plenum).
Open-Plan Offices NC 35 - 40 Standard internal lining and low-velocity branch design.
Hospitals / Wards NC 30 - 35 Antimicrobial acoustic media (Sterile-grade) is mandatory.
Recording Studios NC 15 - 20 Specialized "Double-Walled" acoustic ducting and decoupled hangers.

3. The VFD & Acoustic Relationship

The use of Variable Frequency Drives (VFDs) adds a unique acoustic challenge: Magnetic Hum.

  1. Carrier Frequency Tuning: At EKG (Malaysia) SDN BHD, our engineers tune the VFD's switching frequency (typically between 8kHz and 16kHz) to shift motor noise out of the human audible range, ensuring the AHU remains "Silent."

  2. Resonance Avoidance: We utilize "Skip Frequencies" in the VFD programming to bypass specific RPMs where the ductwork might vibrate or "rumble" due to mechanical resonance.

  3. Low-Velocity Design: To maintain a low SFP (Specific Fan Power) while remaining quiet, we size attenuated ducts for a velocity of 4.0 to 6.0 m/s, preventing the generation of air turbulence noise.


4. The "Fire Mode" Statutory Protocol

Acoustic materials must not compromise the building's fire integrity. Under BOMBA (JBPM) 2026 regulations:


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU causing distracting noise or "duct rumble" in your facility? Contact EKG (Malaysia) SDN BHD today for a specialized Acoustic Sound & Vibration Audit.