In the 2026 Malaysian engineering landscape, a Fire Protection Grade Air Handling Unit (AHU) is a specialized mechanical asset that bridges the gap between climate control and life safety. Following the enforcement of the Fire Services (Fire-fighting Equipment or Fire Safety Installation) Regulations 2026 on February 3, 2026, these units must satisfy rigorous fire-containment and smoke-control mandates to secure a valid AHU Safety Permit.
At EKG (Malaysia) SDN BHD, we engineer Fire Protection Grade AHUs to ensure your building remains Sterile, Silent, and Statutory-Compliant.
Under the Uniform Building By-Laws (UBBL) 2026 and the Fire Services Act 1988 (2025 Amendment), Fire Protection Grade AHUs are subject to three primary pillars of compliance:
Mandatory AHU Safety Permit: Every unit must hold a valid permit issued by BOMBA (Jabatan Bomba dan Penyelamat Malaysia). This serves as the legal proof that the AHU will not facilitate smoke migration during a fire.
eFEIS 2.0 Registration: All fire-safety components integrated into the AHU (dampers, detectors, actuators) must be registered in the eFEIS 2.0 digital system and carry the BOMBA "K" Mark.
EECA 2024 Alignment: Fire-safety modifications must not compromise the unit's Specific Fan Power (SFP). A Fire Protection Grade AHU must still meet the energy intensity targets required for its building category.
A "Fire Protection Grade" unit is distinguished from a standard AHU by its material composition and its ability to respond to active fire signals.
Class 0 Non-Combustible Material: The internal and external skins must be Class 0 rated (typically Galvanized Steel or Stainless Steel) to prevent the AHU from contributing to the fire load.
Mineral Wool / Rockwool Insulation: Unlike standard units that may use PU foam, Fire Protection Grade units utilize high-density mineral wool insulation, which maintains structural integrity and prevents smoke generation at high temperatures.
Intumescent Gaskets: All panel joints and access doors are sealed with intumescent material that expands when exposed to heat, creating a secondary airtight fire seal.
| Component | 2026 Requirement | Purpose |
| Motorized Fire Dampers | MS 558:2024 Certified | Automatically seals duct penetrations in under 20 seconds. |
| Duct Smoke Detectors | Photoelectric / Interlocked | Triggers localized shutdown before smoke recirculates. |
| FR Cabling (Class C) | MS 2116 Compliant | Ensures the shut-off signal survives the high heat of a fire. |
| VSD Fire Mode | Hard-wired Interlock | Allows the fan to be overridden or shut down by the FACP. |
A Fire Protection Grade AHU is programmed with a fail-safe logic interlocked with the building's Fire Alarm Monitoring System (FAMS):
Detection: Smoke is detected by the return air duct sensor or the building’s general fire alarm.
Automatic Shut-off: The IE5 EC Fan Wall receives an immediate "Kill-Signal" via its Variable Speed Drive (VSD).
Isolation: Motorized Fire Dampers revert to their fail-safe closed position using spring-return actuators.
BMS Reporting: The system confirms the "Safe & Isolated" status to the Fire Control Room.
Technical Integrity: Our Fire Protection Grade units are engineered by mechanical specialists who understand the intersection of thermodynamics and active fire protection.
BOMBA Submission Support: We manage the entire Form B submission and coordinate the witness test for the AHU Safety Permit.
GITA Support: Documented compliance with 2026 fire standards is essential proof for claiming the 100% Green Investment Tax Allowance.