Features:
pH:
*Multiparameter water quality meter is equipped with a 6.5 inches backlit LCD display 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
*Automatic electrode diagnosis shows the pH slope and offset.
ORP:
*1 point offset calibration allows adjusting the displayed value to a known standard.
*Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration:
*2 to 5 points calibration, including the 8 concentration points can be selected.
*Direct ion concentration readout simplifies the measurement process.
*Automatic electrode diagnosis shows the calibration points and slopes.
*Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity:
*1 to 5 points calibration with automatic recognition for conductivity standards.
*Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
*Automatic electrode diagnosis shows the calibration points and factors.
Dissolved Oxygen:
*1 or 2 points calibration using the air-saturated water or zero oxygen solution
*Salinity and barometric pressure compensations eliminate the measurement error
Other Features:
*Automatic temperature compensation ensures accurate readings over the entire range.
*Auto-Read function senses and locks the measurement endpoint.
*Calibration due alarm prompts user to calibrate the meter regularly.
*Setup menu allows setting the number of calibration points, resolution, stability criteria,temperature unit,
date and time, etc.
*Reset function automatically resumes all settings back to the factory defaults.
*Expanded memory stores or recalls up to 500 data sets.
*USB communication interface for data transfer and timed interval readings.
 
Technical Parameters:
| Model | PH-900 | |
| pH | Range | -2.000~20.000pH | 
| Resolution | 0.001, 0.01,0.1 pH, selectable | |
| Accuracy | ±0.002pH | |
| Calibration Points | 1 to 5 points | |
| pH Buffer Options | USA, NIST, DIN, 2 custom buffers | |
| ORP(optional) | Range | ±1999.9mV | 
| Resolution | 0.1,1mV, selectable | |
| Accuracy | ±0.2mV | |
| Calibration Points | 1 point | |
| lon(optional) | Range | 0.001-19999 (depending on the range of ISE) | 
| Resolution | 0.001, 0.01,0.1, 1 | |
| Accuracy | ±0.5% F.S. (monovalent),±1%F.S. (divalent) | |
| Measurement Units | ppm, mg/L, mol/L, mmol/L | |
| Calibration Points | 2 to 5 points (0.001, 0.01,0.1, 1,10, 100, 1000, 10000) | |
| Conductivity | Range | 0.1 ~2pS/cm(CON-0.1 .optional); 2-20mS/cm(CON-1 .standard); 20~200mS/cm(CON-10,optional) | 
| Resolution | 0.001,0.01,0.1, 1 | |
| Accuracy | ±0.5% F.S. | |
| Calibration Points | 1 to 5 points | |
| Calibration Solutions | 10pS/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm | |
| Temperature Coefficient | Linear (0.0~10.0%/°C), pure water | |
| Reference Temperature | 20/25P | |
| Cell Constant | K=0.1,1,10 or custom | |
| TDS | Range | 0-10.00, 100.0, 1000ppm, 10.00, 200.0ppt | 
| Resolution | 0.01,0.1,1 | |
| Accuracy | ±1%F.S. | |
| TDS Factor | 0.1-1.0 (default 0.5) | |
| Salinity | Range | 0.00~42.00psu, 0.00~80.00ppt | 
| Resolution | 0.01 | |
| Accuracy | ±1%F.S. | |
| Resistivity | Range | 0.00-20.00MQ | 
| Resolution | 0.01 | |
| Accuracy | ±1%F.S. | |
| DO | Range | 0.00-20.OOmg/L, 0.0*200.0% saturation | 
| Resolution | 0.01 mg/L, 0.1% | |
| Accuracy | ±0.2mg/L, ±2.0% | |
| Calibration Points | 1 or 2 points | |
| Barometric Pressure Correction | 60.0-112.5kPa/450-850mmHg, manual | |
| Salinity Correction | 0.0~50.0g/L, manual | |
| Other Specifications | Temperature Compensation | 0~100°C/32~212°F, manual or automatic | 
| Memory | 500 data sets, USB communication interface | |
| Power Requirements | DC5V power adapter | |
| Dimension | 210*188*60mm | |
| Net Weight | 1.5kg | |
| Packing Size | 300*250*200mm | |
| Gross Weight | 1.7kg | |