www.mysafety.my,
supported by Saturn Pyro Sdn. Bhd., provides professional Arc Flash Hazard Analysis
services for industrial, commercial and utility electrical installations in Malaysia.
Arc flash incidents can expose workers to extreme heat, pressure waves, molten metal, intense light
and serious injury risks. A proper arc flash study helps identify electrical hazards, determine incident
energy levels, define PPE requirements and support safer electrical maintenance practices.
Arc flash hazard analysis provides the technical basis for safer work planning, correct PPE selection,
equipment warning labels, risk reduction actions and improved electrical safety awareness.
Determine the potential arc flash incident energy at electrical equipment so that workers can
understand the severity of the hazard before carrying out work.
Support proper PPE selection based on calculated arc flash energy, working distance and equipment
risk level.
Provide practical recommendations for reducing risk through protection settings, operating procedures,
maintenance practices and safety labelling.
Electrical switchboards, motor control centres, transformers, distribution boards and MV/LV panels can
present serious arc flash risks if fault energy, clearing time and protection performance are not properly
understood. An arc flash study helps translate electrical calculations into practical safety information
for personnel working near energized equipment.
Helps protect electrical workers from severe injury by identifying arc flash energy and PPE needs.
Makes hidden electrical risks visible through calculated incident energy and arc flash boundaries.
Supports clear warning labels for panels, switchboards and electrical equipment.
Provides safety inputs for shutdown planning, electrical isolation and energized work assessment.
The study can be carried out as a dedicated arc flash assessment or together with ETAP power system
studies such as short circuit analysis and protection coordination.
Review single line diagrams, transformer ratings, cable data, switchgear information, protective
device details and available system operating data.
Determine available fault current levels required for arc flash calculations and equipment assessment.
Evaluate protective device operation and clearing time that directly affects arc flash incident energy.
Calculate incident energy, arc flash boundary and risk levels for selected electrical equipment.
Provide PPE guidance based on calculated arc flash levels to support safer electrical work planning.
Prepare label information for electrical panels, switchboards and relevant equipment based on study results.
Deliverables can be tailored based on facility size, available information, equipment list and required study scope.
Arc flash hazard analysis is useful for facilities where personnel carry out electrical switching,
troubleshooting, testing, inspection, maintenance or isolation work.
Assess main LV switchboards, sub-switchboards, distribution boards and power distribution panels.
Review medium voltage switchgear, transformer incomers, feeders and protection arrangements.
Evaluate MCCs, motor feeders and process-related electrical panels used in industrial operations.
Support electrical safety planning for manufacturing plants, utilities, data centres and critical facilities.
A good arc flash study should not stop at calculations. It should help safety teams, engineers and
maintenance personnel understand where the risks are, what PPE is required, what labels should be applied
and what improvements can reduce exposure during electrical work.
Saturn Pyro follows a structured process to ensure the arc flash assessment is based on traceable
electrical information and practical site requirements.
Review SLDs, transformer data, cable details, switchgear ratings, protection devices and equipment list.
Build or update the electrical network model using available site and equipment information.
Perform short circuit, protection clearing time and incident energy calculations for selected equipment.
Provide study report, risk summary, PPE information, label schedule and improvement recommendations.
Saturn Pyro combines electrical engineering, power system study capability and safety-focused field
experience to support practical arc flash risk management.
We connect engineering calculations with practical electrical safety actions for site teams.
Our arc flash work can be integrated with short circuit, protection coordination and ETAP studies.
Our experience covers industrial plants, critical facilities, LV/MV distribution systems and electrical infrastructure.
Contact mysafety.my / Saturn Pyro to request a proposal for arc flash hazard analysis, incident energy
calculation, PPE requirement review, arc flash labels or complete ETAP-based power system safety studies.
Arc Flash Hazard Analysis for Safer Electrical Workplaces
Identify Arc Flash Risk Before Electrical Work Begins
Understand the Hazard
Select Suitable PPE
Improve Safety Control
Why Arc Flash Hazard Analysis Matters
Worker Safety
Risk Visibility
Equipment Labelling
Maintenance Planning
Our Arc Flash Study Scope
Electrical Data Review
Short Circuit Calculation
Protection Clearing Time
Incident Energy Analysis
PPE Requirement Summary
Arc Flash Warning Labels
Typical Deliverables
Arc Flash Study Report
Safety Outputs
Improvement Recommendations
Suitable for Industrial and Commercial Electrical Systems
LV Switchboards
MV Switchgear
Motor Control Centres
Factories & Critical Facilities
Arc Flash Analysis Turns Electrical Calculations into Practical Safety Information
Our Study Process
Data Collection
System Modelling
Arc Flash Calculation
Report & Labelling
Why Work with Saturn Pyro?
Safety-Focused Engineering
Power System Study Experience
Practical Site Understanding
Need an Arc Flash Hazard Analysis?
Malaysia