Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1)
Aluminum die-cast models also available
| 
			 Model  | 
			
			 TL-W5MD[]  | 
		|
| 
			 Sensing distance  | 
			
			 5 mm ±10%  | 
		|
| 
			 Set distance  | 
			
			 0 to 4 mm  | 
		|
| 
			 Differential travel  | 
			
			 10% max. of sensing distance  | 
		|
| 
			 Detectable object  | 
			
			 Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on  | 
		|
| 
			 Standard sensing object  | 
			
			 Iron, 18 × 18 × 1 mm  | 
		|
| 
			 Response frequency *1  | 
			
			 500 Hz  | 
		|
| 
			 Power supply voltage  | 
			
			 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  | 
		|
| 
			 Leakage current  | 
			
			 0.8 mA max.  | 
		|
| 
			 Control  | 
			
			 Load current  | 
			
			 3 to 100 mA  | 
		
| 
			 Residual voltage  | 
			
			 3.3 V max. (under load current of 100 mA with cable length of 2 m)  | 
		|
| 
			 Indicators  | 
			
			 D1 Models: Operation indicator (red), Setting indicator (green)  | 
		|
| 
			 Operation mode  | 
			
			 D1 Models: NO  | 
		|
| 
			 Protection circuits  | 
			
			 Load short-circuit protection, Surge suppressor  | 
		|
| 
			 Ambient temperature range  | 
			
			 Operating/Storage: -25 to 70°C (with no icing or condensation)  | 
		|
| 
			 Ambient humidity range  | 
			
			 Operating/Storage: 35% to 95% (with no condensation)  | 
		|
| 
			 Temperature influence  | 
			
			 ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  | 
		|
| 
			 Voltage influence  | 
			
			 ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range  | 
		|
| 
			 Insulation resistance  | 
			
			 50 MΩ min. (at 500 VDC) between current-carrying parts and case  | 
		|
| 
			 Dielectric strength  | 
			
			 1,000 VAC for 1 min between current-carrying parts and case  | 
		|
| 
			 Vibration resistance  | 
			
			 Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  | 
		|
| 
			 Shock resistance  | 
			
			 Destruction: 500 m/s2 3 times each in X, Y, and Z directions  | 
		|
| 
			 Degree of protection  | 
			
			 IEC 60529 IP67, in-house standards: oil-resistant *2  | 
		|
| 
			 Connection method  | 
			
			 Pre-wired Models (Standard cable length: 2 m)  | 
		|
| 
			 Weight (packed state)  | 
			
			 Approx. 80 g  | 
		|
| 
			 Materials  | 
			
			 Case  | 
			
			 Heat-resistant ABS  | 
		
| 
			 Sensing surface  | 
		||
| 
			 Accessories  | 
			
			 Instruction manual  | 
		|