| Item | Data | ||
| APPROVAL | |||
| Test standard | IEC/EN60998-1:2004 / UL1059 | ||
| Pitch [mm] | 5 | ||
| Poles | 02-XXP | ||
| EN60998 Test data | 40024856 | ||
| Rated voltage [V] | 250 | ||
| Rated current) [A] | 18 | ||
| Rated connection capacity)(solid/stranded) [mm2] | 0.5-2.5 | ||
| Surge voltage category/pollution degree/material group) | III/2/I | ||
| Withstanding Voltage [KV/min] | 2 | ||
| Rated torque [N.m] | 0.34~0.40 | ||
| UL1059Test data | UL File Number E228872 | ||
| Use group | B | C | D |
| Rated voltage [V] | 300 | / | / |
| Rated current [A] | 10 | / | / |
| Rated connection capacity (solid/stranded) [AWG] | 26~14 | ||
| Rated torque [Lb. in] | 3.01~3.54 | ||
| General data | / | ||
| Screw | M2.6 | ||
| Inflammability classUL94 | V-0 | ||
| Ambient temperature [℃] | -40~+105 | ||
| Relative humidity | 5%-95% | ||
| Inspection standard | MIL-STD-105E II | ||
| AQL | 0.65 | ||
| Warranty | 12 months | ||
| Material and plating | / | ||
| Housing | PA66 | ||
| Screws | Steel,Zn plated | ||
| Contact | Copper alloy,Sn Plated | ||
| Wire protector | Stainless steel | ||
| Wire connecting | |||
| 5-6mm; Recommended stripping length 5-6mm; | |||
| 1.)For solid wire, stripping wire to the appointed length, then tightening with rated torque. | |||
| 2.)For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
| Tightening process should be steady, can’t use explosive force. | |||