| Item | Data | ||
| APPROVAL | / | ||
| Test standard | IEC60947/ UL1059 | ||
| Pitch [mm] | 5 | ||
| Poles | 03P | ||
| IEC60947 Test data | / | ||
| Rated voltage [V] | 320 | ||
| Rated current [A] | 10 | ||
| Rated connection capacity (solid/stranded) [mm2] | 0.5-1.5 | ||
| Surge voltage category/pollution degree/material group | III/2/I | ||
| Rate impulse voltage [KV] | 4 | ||
| Rated torque [N.m] | / | ||
| UL1059Test data | UL1059 | ||
| Use group | B | C | D |
| Rated voltage [V] | 300 | / | / |
| Rated current [A] | 10 | / | / |
| Rated connection capacity (solid/stranded) [AWG] | 30-16 | ||
| Rated torque [Lb. in] | / | ||
| General data | / | ||
| Screw | / | ||
| Inflammability class UL94 | V-0 | ||
| Ambient temperature [℃] | -40~+105 | ||
| Relative humidity | 5%-95% | ||
| Inspection standard | MIL-STD-105E II | ||
| AQL | 0.65 | ||
| Warranty | 12 months | ||
| Material and plating | / | ||
| Housing | PA66 | ||
| Spring | Stainless | ||
| Pin header | Copper alloy,Sn plated | ||
| Wire connecting | |||
| Recommended stripping length 10mm; | |||
| 1.)For solid wire, stripping wire to the appointed length ,press button and insert the wire. | |||
| 2.)For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||