| Article | Data |
| APPROVAL | QA mandatory inspection report Link |
| Test standard | IEC 62196.1 -2014 IEC 62196.2 -2014 |
| Charging mode | 3 |
| Connect manner | B,C |
| Current type | AC |
| Work ambient temperature [℃] | -30~+50 |
| Storing ambient temperature [℃] | -40~+80 |
| The tallest elevation [M] | <2000 |
| Ingress protection | Protect cover IP54 |
| Work status IP55 | |
| Rated current [A] | 16A/32A |
| Rated voltage [V] | 250 |
| 480 | |
| Bear voltage [V] | 2500 |
| Power pins | 3(L1、N、PE) |
| 5( L1、L2、L3、N、PE) | |
| The signal contact number | 2(PP、CP) |
| Rated voltage of the signal contact number | 2A |
| Insulate resistance [ MΩ] | >10 |
| Earthing resistance [ Ω] | <0.05 |
| Temperature monitor | / |
| The contact plastic material | PA66,UL94V-0 |
| Surface material | High strength thermoplastic material |
| UL94V-0 | |
| Contact material | Copper alloy+ The coping insulates, Silver- plated |
| The insertion/pullout times [Time] | >10000 |
| Insertion/pullout force [N] | <100 |
| Withstanding impact force | Affordable 1 meter height fell or 2 ton car run over pressure |
| Warranty | 12 months |
| Cable type | PrEN50620 EV 3*2.5mm2+1*0.75mm2 (16A) |
| Recommend stripping length 5.5mm; |