				 Item  | 
			
				 Data  | 
		||
| 
				 APPROVAL  | 
			
				 /  | 
		||
| 
				 Test stand  | 
			
				 IEC/EN60947-7-1:2009 / UL1059  | 
		||
| 
				 Pitch [mm]  | 
			
				 8.20  | 
		||
| 
				 Poles  | 
			
				 01P  | 
		||
| 
				 EN60947-7-1 Test data)  | 
			
				 /  | 
		||
| 
				 Rated voltage) [V]  | 
			
				 500  | 
		||
| 
				 Rated current) [A]  | 
			
				 41  | 
		||
| 
				 Rated connection capacity)(solid/stranded) [mm2]  | 
			
				 0.5-6  | 
		||
| 
				 Surge voltage category/pollution degree/material group)  | 
			
				 III/3/I  | 
		||
| 
				 Rated impulse voltage) [KV]  | 
			
				 6  | 
		||
| 
				 Rated torque) [N.m]  | 
			
				 1.2  | 
		||
| 
				 UL1059Test data)  | 
			
				 /  | 
		||
| 
				 Use group)  | 
			
				 B  | 
			
				 C  | 
			
				 D  | 
		
| 
				 Rated voltage) [V]  | 
			
				 300  | 
			
				 /  | 
			
				 300  | 
		
| 
				 Rated current) [A]  | 
			
				 40  | 
			
				 /  | 
			
				 10  | 
		
| 
				 Rated connection capacity solid/stranded [AWG]  | 
			
				 26-10  | 
		||
| 
				 Rated torque) [Lb. in]  | 
			
				 10.53  | 
		||
| 
				 General data)  | 
			
				 /  | 
		||
| 
				 Screw  | 
			
				 M4  | 
		||
| 
				 Inflammability class)UL94  | 
			
				 V-0  | 
		||
| 
				 Ambient temperature [℃]  | 
			
				 -40~+105  | 
		||
| 
				 Relative humidity  | 
			
				 5%-95%  | 
		||
| 
				 Inspection standard  | 
			
				 MIL-STD-105E II  | 
		||
| 
				 AQL  | 
			
				 0.65  | 
		||
| 
				 Warranty  | 
			
				 12 months  | 
		||
| 
				 terial and plating  | 
			
				 /  | 
		||
| 
				 Housing  | 
			
				 PA66  | 
		||
| 
				 Screws  | 
			
				 Copper alloy,Ni plated  | 
		||
| 
				 Contact  | 
			|||
| 
				 Cage  | 
			
				 Copper alloy,Ni plated  | 
		||
| 
				 Wire connecting  | 
		|||
| 
				 12-13mm; Recommended stripping length 12-13mm;  | 
		|||
| 
				 1.)For solid wire, stripping wire to the appointed length, then tightening with rated torque.  | 
		|||
| 
				 2.)For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. 
  | 
		|||
| 
				 Tightening process should be steady, can’t use explosive force.  | 
		|||