				Technical Specifications | 
		
		
			| 
				DCV | 
			
				
					
						
							| 
								Maximum Voltage: | 
							
								 1000V | 
						 
						
							| 
								Accuracy: | 
							
								 Fluke 88 V: ±(0.1%+1) | 
						 
						
							| 
								Best Resolution: | 
							
								 Fluke 88 V: 0.01 mV | 
						 
					
				 
			 | 
		
		
			| 
				ACV | 
			
				
					
						
							| 
								Maximum Voltage: | 
							
								 1000V | 
						 
						
							| 
								Accuracy: | 
							
								 Fluke 88 V: ±(0.5%+2) | 
						 
						
							| 
								AC Bandwidth: | 
							
								 Fluke 88 V: 5kHz | 
						 
						
							| 
								Best Resolution: | 
							
								 0.01 mV | 
						 
					
				 
			 | 
		
		
			| 
				DC Current | 
			
				
					
						
							| 
								Maximum Amps: | 
							
								 10A | 
						 
						
							| 
								Amps Accuracy: | 
							
								 Fluke 88 V: ±(0.4%+2) | 
						 
						
							| 
								Best Resolution: | 
							
								 Fluke 88 V: 0.001 mA | 
						 
					
				 
			 | 
		
		
			| 
				AC Current | 
			
				
					
						
							| 
								Maximum Amps: | 
							
								 10A | 
						 
						
							| 
								Amps Accuracy: | 
							
								 Fluke 88 V: ±(1.2%+2) | 
						 
						
							| 
								Best Resolution: | 
							
								 0.001 mA | 
						 
					
				 
			 | 
		
		
			| 
				Resistance | 
			
				
					
						
							| 
								Maximum Resistance: | 
							
								 50 MΩ | 
						 
						
							| 
								Accuracy: | 
							
								 Fluke 88 V: ±(0.4%+1) | 
						 
						
							| 
								Best Resolution: | 
							
								 0.1Ω | 
						 
					
				 
			 | 
		
		
			| 
				Capacitance | 
			
				
					
						
							| 
								Maximum Capacitance: | 
							
								 9,999 µF | 
						 
						
							| 
								Accuracy: | 
							
								 ±(1%+2) | 
						 
						
							| 
								Best Resolution: | 
							
								 0.01 nF | 
						 
					
				 
			 | 
		
		
			| 
				Frequency | 
			
				
					
						
							| 
								Maximum Frequency: | 
							
								 200 KHz | 
						 
						
							| 
								Accuracy: | 
							
								 ±(0.005%+1) | 
						 
						
							| 
								Best Resolution: | 
							
								 0.01 Hz | 
						 
					
				 
			 | 
		
		
			| 
				Duty Cycle | 
			
				
					
						
							| 
								Maximum Duty Cycle: | 
							
								 99.9 % | 
						 
						
							| 
								Accuracy: | 
							
								 within 2% per KHz +0.1% | 
						 
						
							| 
								Best Resolution: | 
							
								 0.1 % | 
						 
					
				 
			 | 
		
		
			| 
				Temperature Measurement | 
			
				
					
						
							| 
								  | 
							
								 -200.0°C - 1090°C | 
						 
						
							| 
								  | 
							
								 -328.0°F - 1994.0°F, 1.0% excluding probe | 
						 
					
				 
			 | 
		
		
			| 
				80 BK Temperature Probe | 
			
				
					
						
							| 
								  | 
							
								 -40 °C - 260 °C | 
						 
						
							| 
								  | 
							
								 -40 °F - 500 °F, 2.2 °C or 2% whichever is greater | 
						 
					
				 
			 | 
		
		
			| 
				Conductance | 
			
				
					
						
							| 
								Maximum Conductance: | 
							
								 60.00 nS | 
						 
						
							| 
								Accuracy: | 
							
								 ±(1.0%+10) | 
						 
						
							| 
								Maximum Resolution: | 
							
								 0.01 nS | 
						 
					
				 
			 | 
		
		
			| 
				Operating Range | 
			
				
					
						
							| 
								Operating Temperature: | 
							
								 -20 °C - 55 °C | 
						 
						
							| 
								Storage Temperature: | 
							
								 -40 °C - 60 °C | 
						 
					
				 
			 | 
		
		
			| 
				Physical | 
			
				
					
						
							| 
								  | 
							
								 5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”) | 
						 
						
							| 
								  | 
							
								 624 g (22 oz.) | 
						 
					
				 
			 |