Testing & Commissioning (T&C): AHU Casing Air Leakage Testing (SMACNA Class C)

In the 2026 Malaysian engineering landscape, AHU Casing Air Leakage Testing for SMACNA Class C is the fundamental verification for standard commercial installations. Under the Energy Efficiency and Conservation Act (EECA) 2024, even Class C (the standard leakage class for low-to-medium pressure units) is subject to rigorous audit. A "leaky box" is categorized as systemic energy waste, as the VFD-driven AHU must ramp up its fan speed to compensate for air lost through the casing, directly inflating your Building Energy Intensity (BEI).

At EKG (Malaysia) SDN BHD, we utilize precision pressure-testing rigs to ensure your AHU casing meets the airtightness requirements mandated by the Suruhanjaya Tenaga (ST) and MS 1525:2024.


1. The Statutory Benchmark: SMACNA Class C

Under the SMACNA HVAC Air Duct Leakage Test Manual, Class C represents the allowable leakage for rectangular ductwork and AHU casings. In the context of a 2026 statutory audit, failing to meet this benchmark can lead to the rejection of your building's energy efficiency certification.

Metric SMACNA Class C Target 2026 Statutory Context
Leakage Class ($C_L$) 24 (Rectangular) Standard for general office & retail AHUs.
Max Allowable Leakage Calculated via $F = C_L \times P^{0.65}$ Proof of performance for the REM.
SFP Impact Contribution to 1.6 kW/m³/s cap Minimizing waste to ensure SFP compliance.

2. The EKG Casing Leakage Protocol

We treat the AHU casing as a pressurized vessel, performing a "Static Pressure Test" to quantify the $m^3/h$ of air lost through seams, door gaskets, and panel joints.

  1. System Isolation: All AHU openings (supply, return, and fresh air) are hermetically sealed using temporary blanking plates or high-tack adhesive films.

  2. Pressurization: A calibrated DALT (Duct Air Leakage Testing) rig is connected to the casing. We pressurize the unit to its Design Operating Pressure (typically 500 Pa to 1,000 Pa).

  3. Data Capture: We measure the steady-state airflow required to maintain that pressure. This value is our "Measured Leakage," which is then compared against the SMACNA Class C allowable limit based on the unit's total surface area.

  4. Leak Detection: If the unit exceeds Class C, we utilize non-toxic theatrical smoke or ultrasonic leak detectors to pinpoint failures in AHU Body Restoration or panel seals.


3. Engineering for "Energy & Moisture Integrity"

Meeting Class C is about more than just energy; it is about protecting the building from the 90% humidity of KL and Selangor.


4. The "Fire Mode" Statutory Witness Test

The casing's ability to hold pressure is vital for the life-safety requirements of BOMBA (JBPM) 2026.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU "whistling" away your energy budget through leaky seams?

Contact EKG (Malaysia) SDN BHD today for a professional AHU Casing Air Leakage Test (SMACNA Class C) & Statutory Compliance Audit.