airflow balancing and commissioning

airflow balancing and commissioning

Kategori: Fresh Air & Exhaust Systems Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di eakon.com.my

Penerangan

Airflow Balancing and Commissioning by EKG M&E Sdn Bhd

In the commercial towers and industrial plants of KL and Selangor, an HVAC system is only as good as its final calibration. EKG M&E Sdn Bhd specializes in Airflow Balancing and Commissioning (TAB), the process of adjusting a building's mechanical ventilation to ensure that every room receives the exact volume of air specified in the original design. Without professional balancing, systems often suffer from hot spots, noisy ducts, and skyrocketing energy bills.


The Goals of Professional Airflow Balancing

Air follows the path of least resistance. Without mechanical intervention, rooms closest to the Air Handling Unit (AHU) will be over-cooled, while the furthest offices will remain stuffy and warm.


Our Commissioning (TAB) Process

As an HVAC and Clean Air Specialist, we utilize high-precision M&E instruments to validate your system's performance:

1. Duct Traverse and Velocity Mapping

We use digital anemometers to measure air velocity at multiple points within the main ductwork. This allows us to calculate the total Cubic Meters per Hour (CMH) moving through the system.

2. Terminal Device Balancing

We measure the airflow at every individual supply diffuser and return grille. Using a Flow Hood (Balometer), we adjust the internal dampers until the actual airflow matches the design intent within a 10% tolerance.

3. System Static Pressure Audit

We measure the pressure drop across filter banks and cooling coils. If the pressure is too high, it indicates a blockage or a need for filter replacement; if too low, it suggests a leak in the ductwork.

4. VFD and AHU Synchronization

We program the Variable Frequency Drive (VFD) to deliver the exact static pressure required to push air to the furthest terminal. This prevents the motor from overworking, significantly reducing energy consumption.


Signs Your KL Facility Needs Re-Balancing

Symptom Probable M&E Cause EKG M&E Solution
Whistling Doors Excessive Negative Pressure. Re-balance Intake vs Exhaust.
Stuffy Meeting Rooms Low Air Change Rate (ACR). Increase damper opening/VFD speed.
High Humidity Insufficient Fresh Air / PAHU fault. Calibrate PAHU cooling and airflow.
Noisy AC Grilles Excessive Air Velocity. Adjust branch dampers for quiet flow.

Why Choose EKG M&E Sdn Bhd?