Chilled water pump head calculation

Chilled water pump head calculation

Kategori: Chiller Water Pumps Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di ekg.com.my

Penerangan

 

Chilled Water Pump Head Calculation Precision Engineering by EKG (Malaysia) Sdn Bhd

Accurate Calculation is the Foundation of Efficient Pump Selection
Correct chilled water pump head calculation is the critical engineering step that determines pump size, energy consumption, and system performance. An under-calculated head leads to inadequate flow and poor cooling; an over-calculated head wastes energy and causes operational issues. EKG (Malaysia) Sdn Bhd provides professional hydraulic analysis and head calculation services to ensure your chilled water pump is perfectly matched to your system's actual requirements.

The Total Dynamic Head (TDH) Formula

The pump must overcome the Total Dynamic Head (TDH), which is the sum of all system resistances:

TDH = H + H0 + H + He
Where:

Our Detailed Calculation Process

We methodically calculate each component:

1. Static Head (H ) Determination

2. Friction Head (H0) Calculation

3. Equipment Pressure Drop (H ) Compilation
We sum pressure drops (in meters) for:

4. Special Considerations for Malaysian Projects

Common Calculation Mistakes We Correct

  1. Oversimplification: Using arbitrary "rules of thumb" (e.g., 4 meters per floor) instead of actual calculations.

  2. Ignoring Future Conditions: Not accounting for system aging or additional future loads.

  3. Component Omission: Forgetting pressure drops for strainers, balancing valves, or temperature gauges.

  4. Improper Static Head: Confusing open and closed system static head requirements.

Our Engineering Deliverables

When we perform a head calculation, you receive:

  1. Detailed Calculation Sheet: Showing each component with assumptions and references.

  2. System Curve Plot: Graphical representation of system head vs. flow.

  3. Pump Selection Recommendation: Specific pump models that intersect the system curve at the desired operating point.

  4. Energy Consumption Estimate: Projected pump power at design and partial load conditions.

Why Professional Calculation Matters

Our Calculation Service Includes

Ensure Your Pump Investment is Engineered for Performance and Efficiency
Don't guess—calculate with precision. Let our engineers determine the exact requirements for your chilled water system.

Contact EKG (Malaysia) Sdn Bhd's engineering team for a professional chilled water pump head calculation and system analysis tailored to your specific project.

Lebih maklumat tentang EKG M & E SDN. BHD.
EKG M & E SDN. BHD.
EKG M & E SDN. BHD. Mechanical, Electrical & Plumbing Construction Service Malaysia, Renewable Energy Solar Solutions Provider KL, TVET Academy Education Selangor | Eakon Group