| Article | Data | 
| APPROVAL | QA mandatory inspection report Link | 
| Test standard | GB/T 20234-2015 | 
| Charging mode | 3 | 
| Connect manner | B | 
| Current type | AC | 
| Work ambient temperature [℃] | -30~+50 | 
| Storing ambient temperature [℃] | -40~+80 | 
| The tallest elevation [M] | <5000 | 
| Ingress protection | Protect cover IP54 | 
| Work status IP55 | |
| Rated current [A] | 32 | 
| Rated voltage [V] | 250 | 
| Bear voltage [V] | 2500 | 
| Power pins | 3(L、N、PE) | 
| The signal contact number | 2(CC、CP) | 
| Rated voltage of the signal contact number | 2A | 
| Insulate resistance [MΩ] | >5 | 
| Ground connection resistance [ Ω] | <0.05 | 
| Temperature monitor | PT1000 | 
| The contact plastic material | PA66,UL94V-0 | 
| Contact material | Copper alloy, Ag- plated | 
| The insertion/pullout times [Time] | >10000 | 
| Insertion/pullout force [N] | <100 | 
| Warranty | 12 months | 
| Cable type | 2*6mm²+1*10 mm²+2*0.75mm² |