| Function | Range | Resolution | Accuracy | |
| AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0% + 3 | |
| DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5% + 3 | |
| AC millivolts | 400.0 mV | 0.1 mV | 3.0% + 3 | |
| DC millivolts | 400.0 mV | 0.1 mV | 1.0% + 10 | |
| Diode test2 | 2.000 V | 0.001 V | 10% | |
| Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 | |
| Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 | |
| AC current μA (40 Hz to 400 Hz) | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5% + 3 | |
| AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5% + 3 | |
| AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5% + 3 | |
| DC current μA | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5% + 3 | |
| DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5% + 3 | |
| DC current A | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5% + 3 | |
| Backlight | Yes | |||
| 1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). | ||||
| Function | Overload protection | Input impedance (Nominal) | Common mode rejection ratio | Normal mode rejection ratio | 
| AC volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz | - | 
| AC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - | 
| DC volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz | 
| DC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - | 
| 1 106 V Hz Max | ||||
| General specifications | |
| Maximum voltage between any terminal and earth ground | 1000 V | 
| Display (LCD) | 4000 counts, updates 3/sec | 
| Battery type | 2 AA, NEDA 15A, IEC LR6 | 
| Battery life | 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) | 
| Temperature | |
| Operating | 0 °C to 40 °C | 
| Storage | -30 °C to 60 °C | 
| Relative humidity | |
| Operating humidity | Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C | 
| 40 MΩ range ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C | |
| Altitude | |
| Operating | 2000 m | 
| Storage | 12,000 m | 
| Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | 
| Fuse protection for current inputs | 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. | 
| Size (H x W x L) | 183 x 91 x 49.5 mm | 
| Weight | 455 g | 
| IP rating | IP 40 | 
| Safety | IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 |