Hydro-Air FC1N Sensor (free/total chlorine )

Hydro-Air FC1N Sensor (free/total chlorine )

Category: Analytic Sensor Available
For more information, visit our official website at vodaproasia.com

Description


Specifications (Low Range Free Chlorine Sensor)
Measuring System                              Amperometric Potentiostatic 3-Electrode System
Measuring Range                               0.005 – 2.000 ppm
Electronic                                           Digital Modbus RTU
Slope Drift                                          Approx. <3% per month
Operating Temperature                      0 – 45oC
Temperature Compensation               Automatically by an integrated temperature sensor
Operating Pressure                            0.5 bar in the flow cell
Flow Rate                                          Approx. 15 – 30 L/h in flow cell
pH Range                                           pH 4 – 12, highly reduced dependence on pH value
Run-in Time                                      First start-up approx. 2 hours
Response Time                                 T90 approx. 2 minutes
Slope Calibration                              DPD-1 Method
Interferences                                     Chlorine Dioxide (ClO2) Ozone (O3) Peracetic Acid
Power Supply                                   9 – 30 VDC
Dimension                                       Diameter : 25mm Length : 205mm
Material                                           Microporous Hydrophilic Membrane PVC-U PEEK Stainless Steel 1.4571

Specifications (Middle Range Free Chlorine Sensor)
Measuring System                           Amperometric Potentiostatic 3-Electrode System
Measuring Range                             0.05 – 20.00 ppm
Electronic                                         Digital Modbus RTU
Slope Drift                                        Approx. <3% per month
Operating Temperature                    0 – 45oC
Temperature Compensation             Automatically by an integrated temperature sensor
Operating Pressure                           0.5 bar in the flow cell
Flow Rate                                         Approx. 15 – 30 L/h in flow cell
pH Range                                          pH 4 – 12, highly reduced dependence on pH value
Run-in Time                                      First start-up approx. 2 hours
Response Time                                  T90 approx. 2 minutes
Slope Calibration                              DPD-1 Method
Interferences                                     Chlorine Dioxide (ClO2) Ozone (O3) Peracetic Acid
Power Supply                                   9 – 30 VDC
Dimension                                        Diameter : 25mm Length : 205mm
Material                                            Microporous Hydrophilic Membrane PVC-U PEEK Stainless Steel 1.4571

Specifications (High Range Free Chlorine Sensor)
Measuring System                            Amperometric Potentiostatic 3-Electrode System
Measuring Range                              0.– 2000 ppm
Electronic                                          Digital Modbus RTU
Slope Drift                                        Approx. <3% per month
Operating Temperature                     0 – 45oC
Temperature Compensation             Automatically by an integrated temperature sensor
Operating Pressure                           0.5 bar in the flow cell
Flow Rate                                         Approx. 15 – 30 L/h in flow cell
pH Range                                          pH 5 – 8, 
Run-in Time                                     First start-up approx. 11 hours
Response Time                                 T90 approx. 8 minutes
Slope Calibration                             DPD-1 Method (up to 10 ppm)
Interferences                                    Chlorine Dioxide (ClO2) Ozone (O3) Peracetic Acid
Power Supply                                   9 – 30 VDC
Dimension                                        Diameter : 25mm Length : 205mm
Material                                            Microporous Hydrophilic Membrane PVC-U PEEK Stainless Steel 1.4571

Specifications (Total Chlorine Sensor)
Measuring System                           Amperometric Potentiostatic 3-Electrode System
Measuring Range                              0.05 – 20.00 ppm
Electronic                                         Digital Modbus RTU
Slope Drift                                        Approx. <3% per month
Operating Temperature                     0 – 45oC
Temperature Compensation              Automatically by an integrated temperature sensor
Operating Pressure                            0.5 bar in the flow cell
Flow Rate                                          Approx. 15 – 30 L/h in flow cell
pH Range                                           pH 4 – 12, 
Run-in Time                                       First start-up approx. 2 hours
Response Time                                   T90 approx. 3 minutes
Slope Calibration                               DPD-1 Method
Interferences                                      Chlorine Dioxide (ClO2) Ozone (O3) Peracetic Acid
Power Supply                                     9 – 30 VDC
Dimension                                         Diameter : 25mm Length : 205mm
Material                                             Microporous Hydrophilic Membrane PVC-U PEEK Stainless Steel 1.4571
 