Description
BUY SP3485EN SP3485EN-L/TR 8SOIC https://www.utsource.net/itm/p/9528630.html
| Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
| Operating Supply Voltage |
VCC |
|
4.75 |
5.00 |
5.25 |
V |
| Input Current |
IIN |
VIN = 5V, No Load |
- |
1.0 |
2.0 |
mA |
| Output Current |
IOUT |
VOUT = 5V, Continuous |
0 |
15 |
20 |
mA |
| Common-Mode Input Voltage |
VCM |
|
-7 |
- |
12 |
V |
| Differential Input Voltage |
VDIF |
|
-0.3 |
- |
0.3 |
V |
| Output High Voltage |
VOH |
IOL = -4mA |
4.4 |
- |
5.0 |
V |
| Output Low Voltage |
VOL |
IOL = 16mA |
0 |
- |
0.4 |
V |
| Propagation Delay |
tpd |
VCC = 5V, VIN = 0 to 5V |
15 |
25 |
35 |
ns |
| Skew |
tskew |
VCC = 5V, VIN = 0 to 5V |
- |
2 |
5 |
ns |
| Operating Temperature |
TA |
Storage |
-40 |
- |
85 |
°C |
| Storage Temperature |
TSTG |
|
-55 |
- |
125 |
°C |
Instructions for SP3485EN SP3485EN-L/TR 8SOIC:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 4.75V to 5.25V.
- Use a stable power source to avoid voltage fluctuations that can affect performance.
Input and Output Connections:
- Connect the input signals to the appropriate pins, ensuring they do not exceed the common-mode and differential input voltage ranges.
- The output current should not exceed 20mA continuously to prevent damage to the device.
Signal Integrity:
- Keep signal traces short and use proper grounding techniques to minimize noise and interference.
- Use termination resistors if necessary to match the characteristic impedance of the transmission lines.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C) to ensure reliable performance.
- Store the device in a temperature-controlled environment between -55°C and 125°C.
Handling and Installation:
- Handle the device with care to avoid static discharge and physical damage.
- Follow standard surface mount technology (SMT) procedures for installation on PCBs.
Testing and Troubleshooting:
- Use a multimeter to verify the supply voltage and output voltages.
- Check for any shorts or open circuits in the connections.
- If the device does not function as expected, refer to the datasheet for troubleshooting tips and contact the manufacturer for further assistance.
Compliance:
- Ensure the device complies with all relevant safety and regulatory standards for your application.
- Consult the datasheet for detailed compliance information and certifications.
(For reference only)
More detail about Utsource Holding Company Limited