| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Conditions |
| Supply Voltage |
VDD |
4.5 |
- |
55 |
V |
- |
| Operating Temperature Range |
TA |
-40 |
- |
150 |
°C |
- |
| Maximum Current per Bridge |
IB |
- |
- |
2.5 |
A |
Tj = 150°C, VDD = 55V |
| Maximum Current per Phase |
IP |
- |
- |
1.25 |
A |
Tj = 150°C, VDD = 55V |
| Standby Current |
ISTBY |
- |
10 |
20 |
μA |
VDD = 5V |
| Operating Frequency |
fOP |
- |
20 |
50 |
kHz |
- |
| Thermal Shutdown Temperature |
TSD |
- |
170 |
- |
°C |
- |
| Under-Voltage Lockout (UVLO) Threshold |
VUVLO |
4.0 |
- |
4.5 |
V |
- |
| Over-Voltage Lockout (OVLO) Threshold |
VOVLO |
58 |
- |
60 |
V |
- |
| Internal Power Dissipation |
PD |
- |
- |
3.5 |
W |
TA = 25°C, θJA = 35°C/W |
Instructions for A3953SB:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 4.5V to 55V.
- Use a stable power source to avoid voltage fluctuations that could trigger the UVLO or OVLO.
Temperature Management:
- Operate the device within the temperature range of -40°C to 150°C.
- Monitor the junction temperature (Tj) to prevent thermal shutdown at 170°C.
Current Handling:
- Do not exceed the maximum current per bridge (IB) of 2.5A or the maximum current per phase (IP) of 1.25A to avoid damage.
- Use appropriate heat sinks or cooling methods if operating near the maximum current limits.
Frequency Operation:
- The operating frequency (fOP) should be between 20kHz and 50kHz for optimal performance.
Standby Mode:
- In standby mode, the current consumption (ISTBY) is typically between 10μA and 20μA.
- Use the standby mode to reduce power consumption when the device is not in active use.
Protection Features:
- The device includes under-voltage lockout (UVLO) and over-voltage lockout (OVLO) to protect against supply voltage issues.
- The UVLO threshold is 4.0V to 4.5V, and the OVLO threshold is 58V to 60V.
Thermal Considerations:
- Ensure adequate heat dissipation to keep the internal power dissipation (PD) below 3.5W at ambient temperatures up to 25°C.
- Use a heatsink with a thermal resistance (θJA) of 35°C/W or better to maintain safe operating conditions.
Handling and Storage:
- Store the device in a dry, cool environment to prevent moisture damage.
- Handle the device with care to avoid static discharge, which can damage sensitive components.
By following these parameters and instructions, you can ensure reliable and efficient operation of the A3953SB.
(For reference only)
More detail about Utsource Holding Company Limited