Description
BUY TLP2355 https://www.utsource.net/itm/p/5291342.html
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Conditions |
| Input Forward Voltage |
VIF |
- |
1.2 |
1.6 |
V |
IF = 10 mA |
| Input Current |
IF |
- |
- |
50 |
mA |
VIF = 5 V |
| Output Collector-Emitter Saturation Voltage |
VCE(sat) |
- |
0.3 |
0.5 |
V |
IC = 100 mA, VCE = 5 V |
| Output Collector Current |
IC |
- |
- |
150 |
mA |
VCE = 5 V |
| Isolation Voltage |
VIORM |
- |
- |
5000 |
Vrms |
1 minute, 50/60 Hz |
| Operating Temperature |
TOP |
-40 |
- |
110 |
°C |
- |
| Storage Temperature |
TSTG |
-40 |
- |
125 |
°C |
- |
Instructions for Use:
Input Connection:
- Connect the input side (anode and cathode) to the control signal source.
- Ensure the input current does not exceed 50 mA to avoid damage.
Output Connection:
- Connect the output side (collector and emitter) to the load circuit.
- The maximum collector current should not exceed 150 mA to prevent overheating and potential failure.
Isolation:
- The device provides isolation up to 5000 Vrms for 1 minute at 50/60 Hz. Ensure that the isolation voltage is not exceeded to maintain safety and functionality.
Temperature Considerations:
- The operating temperature range is from -40°C to 110°C. Avoid operating the device outside this range to ensure reliable performance.
- The storage temperature range is from -40°C to 125°C. Store the device in a suitable environment to prevent damage.
Handling:
- Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
- Use appropriate ESD protection measures when handling the device.
Mounting:
- Ensure proper mounting and soldering techniques to avoid thermal and mechanical stresses.
- Follow the recommended PCB layout guidelines to optimize performance and reliability.
Testing:
- Before finalizing the design, conduct thorough testing under various conditions to ensure the device meets the required specifications and performance criteria.
(For reference only)