Description
BUY TLP541G(N https://www.utsource.net/itm/p/5293953.html
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Notes |
| Forward Voltage |
VF |
1.0 |
1.2 |
1.4 |
V |
@ IF = 5 mA |
| Peak Forward Current |
IF(surge) |
- |
- |
100 |
mA |
tP = 10 ms, duty cycle 1% |
| Continuous Forward Current |
IF |
- |
5 |
- |
mA |
@ TA = 25°C |
| Reverse Voltage |
VR |
- |
- |
5 |
V |
@ IR = 1 μA |
| Output Collector-Emitter Saturation Voltage |
VCE(sat) |
0.3 |
0.4 |
0.5 |
V |
@ IF = 5 mA, IC = 5 mA |
| Output Collector Current |
IC |
- |
500 |
- |
mA |
@ VCE = 5 V |
| Isolation Voltage |
VI |
- |
- |
2500 |
VRMS |
@ 1 minute, 50/60 Hz |
| Operating Temperature Range |
TOP |
-40 |
- |
85 |
°C |
- |
| Storage Temperature Range |
TSTG |
-40 |
- |
100 |
°C |
- |
Instructions for Using TLP541G
Mounting:
- Ensure that the device is mounted on a PCB with proper soldering to ensure good electrical connections.
- Avoid mechanical stress on the leads during soldering and handling.
Electrical Connections:
- Connect the anode (A) and cathode (K) pins to the input side of the circuit.
- Connect the collector (C) and emitter (E) pins to the output side of the circuit.
- Ensure that the reverse voltage across the diode does not exceed 5V to avoid damage.
Forward Current:
- The continuous forward current should not exceed 5 mA at ambient temperature (25°C).
- For surge conditions, the peak forward current can be up to 100 mA for a pulse duration of 10 ms with a duty cycle of 1%.
Output Current:
- The output collector current should not exceed 500 mA to ensure reliable operation and prevent overheating.
Isolation:
- The device provides an isolation voltage of up to 2500 VRMS for 1 minute at 50/60 Hz. Ensure that this rating is not exceeded to maintain safety and functionality.
Temperature Considerations:
- The operating temperature range is from -40°C to 85°C. Ensure that the device operates within this range to avoid thermal stress.
- The storage temperature range is from -40°C to 100°C. Store the device in a dry and cool environment to prevent degradation.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Use appropriate ESD protection measures when handling the device.
Testing:
- Before final assembly, test the device using the specified parameters to ensure it meets the required performance criteria.
- Use a multimeter or an oscilloscope to verify the forward voltage and output characteristics.
By following these instructions, you can ensure the reliable and safe operation of the TLP541G optocoupler in your application.
(For reference only)
More detail about Utsource Holding Company Limited