Description
BUY TLP181(GB.TPL.F https://www.utsource.net/itm/p/9509631.html
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Conditions |
| Forward Voltage |
VF |
- |
1.2 |
1.5 |
V |
IF = 20 mA |
| Peak Forward Current |
IF(P) |
- |
- |
30 |
mA |
tp = 10 ms, Duty Cycle ≤ 1% |
| Continuous Forward Current |
IF |
- |
- |
20 |
mA |
Ta = 25°C |
| Reverse Voltage |
VR |
- |
- |
5 |
V |
|
| Output Collector-Emitter Saturation Voltage |
VCE(sat) |
- |
0.3 |
0.6 |
V |
IF = 20 mA, IC = 100 mA |
| Output Collector Current |
IC |
- |
- |
100 |
mA |
VCE = 5 V |
| Output Turn-On Time |
ton |
- |
1 |
4 |
μs |
IF = 20 mA, RL = 1 kΩ, VCC = 5 V |
| Output Turn-Off Time |
toff |
- |
1 |
4 |
μs |
IF = 20 mA, RL = 1 kΩ, VCC = 5 V |
| Storage Temperature Range |
Tstg |
-40 |
- |
100 |
°C |
|
| Operating Temperature Range |
TA |
-40 |
- |
85 |
°C |
|
Instructions for Use:
Forward Current (IF):
- Ensure that the forward current does not exceed 20 mA continuously to avoid damaging the device.
- For peak conditions, the forward current can be up to 30 mA, but only for short durations (tp = 10 ms) and with a duty cycle of ≤ 1%.
Reverse Voltage (VR):
- The device should not be subjected to reverse voltages exceeding 5 V to prevent breakdown.
Collector-Emitter Saturation Voltage (VCE(sat)):
- When the device is on, the collector-emitter voltage should be kept below 0.6 V to ensure efficient operation. This is typically achieved with a forward current of 20 mA and a collector current of 100 mA.
Collector Current (IC):
- The maximum collector current should not exceed 100 mA to avoid overheating and potential damage to the device.
Turn-On and Turn-Off Times:
- The turn-on and turn-off times are crucial for high-speed applications. Ensure that the load resistance (RL) and supply voltage (VCC) are within the specified ranges to achieve the typical values of 1 μs.
Temperature Considerations:
- Store the device within the temperature range of -40°C to 100°C.
- Operate the device within the temperature range of -40°C to 85°C to ensure reliable performance.
Mounting and Handling:
- Handle the device with care to avoid mechanical stress or damage.
- Follow proper soldering techniques to ensure good electrical connections and prevent thermal damage.
Electrostatic Discharge (ESD) Protection:
- Use appropriate ESD protection measures during handling and assembly to prevent damage from static electricity.
By adhering to these parameters and instructions, you can ensure the reliable and efficient operation of the TLP181(GB.TPL.F optocoupler.