74HCT139

74HCT139

Category: Elec-component Available (Qty:9999999)
For more information, visit our official website at utsource.us

Description

BUY 74HCT139 https://www.utsource.net/itm/p/98083.html
Dual 2-to-4 line decoder/demultiplexer2-4/

Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage VCC - 2.0 - 6.0 V
Input Low Voltage VIL IL = 1.0 mA 0.4 - 0.8 V
Input High Voltage VIH IH = -0.4 mA 2.0 - 3.5 V
Output Low Voltage VOL IOL = 4.0 mA 0.1 - 0.4 V
Output High Voltage VOH IOH = -0.4 mA 2.4 - 5.0 V
Input Leakage Current IIL VCC = 5.0 V -1.0 - 1.0 μA
Output Sink Current IOL VCC = 5.0 V 4.0 - 20 mA
Output Source Current IOH VCC = 5.0 V -0.4 - -10 mA
Propagation Delay Time tpd VCC = 5.0 V - 15 35 ns
Power Dissipation Ptot TA = 25°C - - 500 mW
Operating Temperature Range TA - -40 - 85 °C

Instructions for Using the 74HCT139:

  1. Supply Voltage (VCC):

    • The 74HCT139 operates within a supply voltage range of 2.0 V to 6.0 V. Ensure the power supply is stable and within this range to avoid damage to the device.
  2. Input Voltages:

    • Input Low Voltage (VIL): For an input to be recognized as low, it should be between 0.4 V and 0.8 V.
    • Input High Voltage (VIH): For an input to be recognized as high, it should be between 2.0 V and 3.5 V.
  3. Output Voltages:

    • Output Low Voltage (VOL): When an output is low, it should not exceed 0.4 V under a load of 4.0 mA.
    • Output High Voltage (VOH): When an output is high, it should be at least 2.4 V under a load of -0.4 mA.
  4. Current Ratings:

    • Input Leakage Current (IIL): The maximum leakage current through an input pin is ±1.0 μA.
    • Output Sink Current (IOL): The maximum current that can be sunk by an output pin is 20 mA.
    • Output Source Current (IOH): The maximum current that can be sourced by an output pin is -10 mA.
  5. Propagation Delay Time (tpd):

    • The typical propagation delay time is 15 ns, with a maximum of 35 ns at a supply voltage of 5.0 V.
  6. Power Dissipation (Ptot):

    • The maximum power dissipation is 500 mW at an ambient temperature of 25°C. Ensure proper heat dissipation if operating near this limit.
  7. Operating Temperature Range (TA):

    • The device can operate over a temperature range from -40°C to 85°C.
  8. Handling Precautions:

    • Handle the 74HCT139 with care to avoid static damage. Use appropriate ESD protection measures.
    • Ensure all connections are secure and free from shorts or open circuits.
  9. Application Notes:

    • The 74HCT139 is a dual 1-of-4 decoder/demultiplexer. It can be used to decode binary inputs into one of four outputs, making it useful in digital logic circuits for address decoding, multiplexing, and other control applications.