Description
BUY HD74HC240P https://www.utsource.net/itm/p/1465369.html
BUFFER/DRIVER|DUAL|4-BIT|HC-CMOS|DIP|20PIN|PLASTIC
| Parameter |
Symbol |
Conditions |
Min |
Typical |
Max |
Unit |
| Supply Voltage |
VCC |
- |
2.0 |
- |
6.0 |
V |
| Input Voltage (High Level) |
VIH |
- |
3.15 |
- |
VCC |
V |
| Input Voltage (Low Level) |
VIL |
- |
0 |
- |
0.85 |
V |
| Output Voltage (High Level) |
VOH |
IOL = 0.4 mA |
2.4 |
- |
VCC - 0.1 |
V |
| Output Voltage (Low Level) |
VOL |
IOH = -0.4 mA |
0 |
- |
0.1 |
V |
| Input Leakage Current |
IIL |
VCC = 4.5 V to 5.5 V |
-1 |
- |
1 |
μA |
| Output Leakage Current |
IOL |
VCC = 4.5 V to 5.5 V |
-1 |
- |
1 |
μA |
| Propagation Delay Time |
tpd |
VCC = 4.5 V, TA = 25°C, fL = 10 MHz |
6 |
- |
18 |
ns |
| Power Consumption |
Ptot |
VCC = 4.5 V to 5.5 V, fL = 10 MHz |
- |
15 |
- |
mW |
Instructions for Use:
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 2.0 V to 6.0 V.
- Avoid exceeding the maximum voltage to prevent damage to the device.
Input Voltage Levels:
- High-level input voltage (VIH) should be at least 3.15 V when VCC is 5 V.
- Low-level input voltage (VIL) should not exceed 0.85 V when VCC is 5 V.
Output Voltage Levels:
- When sourcing current (IOH = -0.4 mA), the output high voltage (VOH) should be at least 2.4 V.
- When sinking current (IOL = 0.4 mA), the output low voltage (VOL) should not exceed 0.1 V.
Leakage Current:
- Input and output leakage currents should be kept within ±1 μA to ensure proper operation.
Propagation Delay Time (tpd):
- The propagation delay time should be within 6 to 18 ns under typical operating conditions (VCC = 4.5 V, TA = 25°C, fL = 10 MHz).
Power Consumption:
- The total power consumption should not exceed 15 mW under typical operating conditions.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store in a dry, cool place away from direct sunlight and moisture.
Mounting and Soldering:
- Follow recommended soldering profiles to avoid thermal stress.
- Ensure proper alignment and secure mounting to prevent mechanical stress.
Testing and Verification:
- Verify all connections and parameters after assembly to ensure correct operation.
- Use appropriate test equipment to measure input and output voltages, propagation delay, and power consumption.
By following these instructions, you can ensure reliable and efficient operation of the HD74HC240P.
(For reference only)
More detail about Utsource Holding Company Limited