Description
BUY 2SK4108 K4108 https://www.utsource.net/itm/p/8647079.html
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
| Drain-Source Voltage |
Vds |
- |
300 |
- |
V |
| Gate-Source Voltage |
Vgs |
-20 |
- |
10 |
V |
| Continuous Drain |
Id |
- |
15 |
- |
A |
| Pulse Drain |
Idp |
- |
30 |
- |
A |
| Input Capacitance |
Ciss |
- |
2600 |
- |
pF |
| Output Capacitance |
Coss |
- |
1100 |
- |
pF |
| Reverse Transfer |
Crss |
- |
750 |
- |
pF |
| Gate Threshold |
Vth |
2 |
4 |
6 |
V |
| On-State Resistance |
Rds(on) |
- |
0.09 |
- |
Ω |
| Power Dissipation |
Ptot |
- |
180 |
- |
W |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within safe limits.
- Use appropriate mounting hardware to secure the device.
Biasing:
- Apply the gate-source voltage (Vgs) within the specified range to control the drain current (Id).
- Ensure that the gate is properly biased to avoid damage to the device.
Operation:
- Operate the device within the specified drain-source voltage (Vds) and drain current (Id) limits.
- For pulse operation, ensure that the pulse drain current (Idp) does not exceed the maximum rating.
Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid mechanical stress or damage to the leads.
Testing:
- Use appropriate test equipment to verify the parameters before installation.
- Ensure that the test conditions match the specifications provided in the table.
Safety:
- Always follow safety guidelines when handling high-voltage and high-current circuits.
- Use protective equipment such as gloves and safety glasses when necessary.
(For reference only)
More detail about Utsource Holding Company Limited