Description
BUY BSR14 https://www.utsource.net/itm/p/11279209.html
BSR14 NPN Transistors(BJT) 75V 800mA/0.8A 300MHz 100~300 1V SOT-23/SC-59 marking U8 switch and linear application
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Description |
| Forward Voltage |
VF |
- |
1.2 |
1.8 |
V |
Voltage at IF = 500 mA |
| Reverse Voltage |
VR |
- |
- |
500 |
V |
Maximum reverse voltage |
| Forward Current |
IF |
- |
- |
1000 |
mA |
Maximum forward current (pulse) |
| Reverse Current |
IR |
- |
5 |
100 |
μA |
Leakage current at VR = 500 V |
| Power Dissipation |
PT |
- |
- |
2000 |
mW |
Maximum power dissipation |
| Operating Junction Temperature |
TJ |
-40 |
- |
125 |
°C |
Operating temperature range |
| Storage Temperature |
TS |
-55 |
- |
150 |
°C |
Storage temperature range |
| Thermal Resistance |
RθJC |
- |
5 |
- |
°C/W |
Junction to case thermal resistance |
Instructions for Use:
Forward Voltage (VF):
- Ensure that the forward voltage across the diode does not exceed 1.8V when the forward current is 500 mA.
Reverse Voltage (VR):
- The maximum reverse voltage should not exceed 500V to prevent breakdown.
Forward Current (IF):
- The maximum continuous forward current should not exceed 1000 mA. For pulse applications, ensure the current does not exceed this value for extended periods to avoid overheating.
Reverse Current (IR):
- The reverse leakage current should be kept below 100 μA at a reverse voltage of 500V to maintain optimal performance.
Power Dissipation (PT):
- The maximum power dissipation is 2000 mW. Ensure adequate heat sinking if operating near this limit to prevent thermal damage.
Operating Junction Temperature (TJ):
- The operating junction temperature should be within the range of -40°C to 125°C to ensure reliable operation.
Storage Temperature (TS):
- Store the diode in an environment with temperatures ranging from -55°C to 150°C to prevent damage.
Thermal Resistance (RθJC):
- The thermal resistance from the junction to the case is 5°C/W. Use appropriate cooling methods to manage heat dissipation effectively.
Handling and Storage:
- Handle the diode with care to avoid mechanical damage.
- Store in a dry, cool place to prevent moisture damage.
- Avoid exposing the diode to extreme temperatures or corrosive environments.
Mounting:
- Ensure proper mounting to maintain good thermal contact and prevent mechanical stress.
- Use appropriate soldering techniques and avoid excessive heat during soldering to prevent damage to the diode.